8
SETTING TO A TANK
Handle Belt.
Handle Belt.
Belt Pad.
Harness.
Tank Buckle.
Slide
..
Slide
.
【
Note
】
○Install a B. C. to a tank before setting a regulator first
stage.
Install B.C. to a Tank
In the state that a tank buckle is
set in direction of a figure, pull
the end portion of a belt, and
tighten a tank.
While pulling the end of the
belt, turn the tank buckle.
Stick the end of the belt to
the Velcro portion of the
belt.
Slide a tank buckle and a belt
pad in right and left over the
belt so that their position may
become close to the harness
side. Pass a tank belt through
the 2 slits of a tank buckle as
shown in a figure, and make a
tank belt ring large enough for a
tank goes through.
Having a tank belt, move it
up and down and check
w h e t h e r t h e t a n k b e l t
moves. If it moves, please
start it again from the
beginning.(Refer to page
17 for the way to remove.)
Warning
●Please put the tank on the stable place, such as the flat
ground, at the time of setting. It is dangerous if it falls.
●Please be careful not to catch a handle belt between a
tank and B. C. at the time of setting. Not only you cannot
use a handle belt, but also a tank is not fixed firmly.
Make a tank head belt
level.
Put the ring of a tank belt over the
top of the tank. Set a direction of a
tank so that the air exit side of a
tank valve may turn to the back side
at the time of wear.
Also, adjust the setting height of
B.C. so that a tank head belt may
be fixed at the lower portion of a
tank valve in the level state, and
then tighten it.
Be careful not to tighten a tank
head belt too much at this time.
2
1
5
4
3
1
2
3
Figure showing
the way to pass
the belt.
【
Note
】
○A handle belt is a handle for carrying the whole tank,
after setting B. C. to a tank.
Install a B.C. Hose
Warning
●When you perform the connecting work of a B. C. hose,
close the tank valve, push the purge button of a regulator
to release the pressurized air in a hose.
INSTALLATION OF B.C. HOSE
1
Install a regulator first stage to tank valve according to
an operating manual of the regulator.
2
Connect a quick-coupler at
the end of a B. C. hose to a
nose while sliding a collar of
the quick-coupler.
Nose
Collar
3
Grip the end of the quick-
coupler and push it until it
sounds "click".
4
While pulling the quick-coupler by gripping the end of it,
check whether it comes off.
When it comes off, please start it again from the
beginning.
Open a tank valve according to an operating manual of a
regulator or a gauge. Touch the connecting portion with your
fingers to check if air leaks or not. Also, check if you can
hear the sound of air leakage,
If air leaks, once disconnect the quick-coupler and connect it
again from the beginning after pushing a purge button of a
regulator second stage to release air pressure in a hose,
and then check air leakage again.
Check the Connecting Portion of B.C. Hose
Warning
●If there is an air leakage from a connecting portion, do
not use it.
●When the air leakage from a connecting portion does not
stop, please consult with your original dealer or
authorized distributor of our company.
□Disconnect B.C. hose.
Warning
●Before disconnecting a quick-coupler of B.C. hose from
inflator, be sure to close the tank valve, push the purge
button of a regulator to release the pressurized air in a
hose.
Pull the collar of a quick-coupler at the end of a B. C.
hose and disconnect from the nose while pulling the
collar.
Close the tank valve, push the purge button of regulator
second stage to release residual air in a hose.
1
2