28

3.6

OUTSIDE AIR KIT

The installation of an outside air assembly is required on the BIS PANORAMA.

The outside air assembly must be installed according to the following requirements:

1.

 

Duct length should be kept to a minimum.  The maximum length of a 4" I.D. (100mm)
insulated flexible duct is 20 ft. (6.1 m). The duct can be extended to  a maximum of 40
ft. (12 m) using a 6" I.D. (150mm) insulated flexible duct.

2.

 

The air intake register must  not  be installed  more  than  10  ft.  (3050  mm)  above  the
base of the fireplace.

3.

 

The fresh air must  come from outside the house.   The  air  intake  must  not  draw  air
from the attic, from the basement or garage.

4.

 

The air intake register should be installed where it is not likely to  be blocked by  snow
or exposed to extreme wind and well away from automobile exhaust fumes, gas meters
and other vents.

5.

 

The duct and register may be installed above or below floor level.

3.6.1 Outside Air Installation

Make a 4 _" (110 mm) hole in the outside wall of the house at the chosen location. From
outside, place the outside air register in the hole (open  side down) and fasten the register
to the wall, with screws as shown (see figure 22).  Slip the pipe  into the insulated sleeve.
Place  the  insulated  pipe  over  the  register  tube  and  over  the  fireplace’s  outside  air
connector (see figure 23). At each end, carefully pull back the insulation and plastic  cover
exposing the flexible pipe.  Using the aluminium tape provided, wrap  the tape  around the
joint between the flexible pipe and the air inlets. Carefully push  the insulation and plastic
cover back over the pipe.  Using aluminium tape, fasten the plastic cover in place.

 

Figure 22

Figure 23

Summary of Contents for PANORAMA

Page 1: ...sponsible for damages Install the fireplace only as described in these instructions PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE WARNING The fireplace cannot be operated without a door Consult your dealer to select the correct door model 2125 Monterey St Laval Quebec Canada H7L 3T6 Printed in Canada Rev 8 Oct 2006 PIBISPANO Hot Do not touch The glass and surfaces of this appliance will be hot du...

Page 2: ...nty Security Chimneys International Ltd will repair or replace at no charge any plated door or façade that is found to be defective and will assume the necessary labour costs to replace this part 3 During the sixth through the twenty fifth year of the limited warranty Security Chimneys International Ltd will provide replacement parts if available and as described in the document Details of the Lim...

Page 3: ...rs Exclusions Brass accessories installed on the fireplace trims louvers surround kits Conditions 1 The 25 year warranty begins from the date of purchase of the fireplace and is valid as long as this fireplace remains installed in its original home The fireplace must be installed operated and maintained in accordance with the instructions described in the installation manual provided with it Any a...

Page 4: ...3 3 1 7 Refractory Brick Replacement 3 3 1 8 Door Installation 3 3 1 9 Door Adjustment 3 3 1 10 Glass Care Replacement 3 3 1 11 Glass Care Cleaning 3 3 1 12 Gasket Replacement 3 4 FIREPLACE INSTALLATION 14 3 4 1 1 Locating The BIS PANORAMA 3 4 1 2 Hearth Extension Requirements 3 4 1 3 Framing Facing and Mantel 3 5 HOT AIR DUCTING INSTALLATION 19 3 5 1 1 Gravity Kit 3 5 1 2 Forced Air Kit not teste...

Page 5: ...in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Caution Never use gasoline kerosene charcoal lighter fluid or similar liquids to start or rekindle a fire in this fireplace Keep all such liquids well away from the fireplace at all times Caution Keep combustible materials at least 48 inches away from the front of the fir...

Page 6: ...2 ...

Page 7: ...3 2 CERTIFICATION LABEL ...

Page 8: ...ended for use with a gas log Failure to follow these instructions will void the certification and the warranty of the fireplace and may result in an unsafe installation 3 1 1 Parts Required Fireplace model BIS PANORAMA Door set Louver set Del Sol Diamante Fiori or Luna 7 diameter chimney model Secure TempASHT Secure TempS 2100 Nova TempHT6000 Nova TempHT6103 or ACBI manufactured by Security Chimne...

Page 9: ...lowing the unit is overheating 3 2 2 First Fires Before using the fireplace make sure to remove the plastic wrapping on the doors Remove all remaining glue with mild soap Ensure that the door is well adjusted before starting a fire see page 12 The first 5 or 6 fires should be small fires of short duration about 30 to 60 minutes This will help cure the refractory bricks Ashes that will accumulate i...

Page 10: ...l chimney cleaner it can make the catalyst inactive 3 2 4 Combustion Control There is no flue damper in the BIS PANORAMA As is common with airtight stoves the combustion air damper controls the air entering the firebox This allows for a more precise control of the fire The combustion air damper knob is located on the left of the bottom louver It is opened when moved completely to the left This con...

Page 11: ... depend on many factors including chimney length and the moisture content of the wood For instance a long chimney will necessitate closing the damper more To obtain the proper combustion close the damper completely and then open it about _ to _ Three medium size pieces of wood should be burning on a bed of hot coals The heat output will be approximately 35 000 BTU per hour and the loading time wil...

Page 12: ...s for the catalytic combustor E Set the air control at the desired setting The unit will burn best with 2 3 pieces of cordwood spaced 1 to 2 inches apart and allowing air to get under the fuel Criss crossing or arranging the fuel so that air can get underneath will help the fire get started easily 3 2 9 Refuelling For Best Performance To refuel the BIS PANORAMA at the end of a burn cycle where onl...

Page 13: ...s continue to smoke it is probably for one of the following reasons 1 The door is partly open Open the door fully 2 Negative pressure in the house As the fire burns air goes up the chimney This air must be replaced through leakage into the house or through the outside air duct When operating the BIS PANORAMA open a nearby window temporarily to check if there is adequate air replacement 3 Fans oper...

Page 14: ...er and light it Then hold it in the upper part of the firebox to warm up the chimney Wait until the draught is sufficient and then start the fire 8 Blower for central forced air kit operating Not EPA approved Make sure that the blower is at the off position when you open the fireplace doors for reloading 3 2 11 Important Notes 1 Do not block the hot air vents of the fireplace as this will cause th...

Page 15: ...fied chimney sweep If you wish to clean it yourself we recommend using a stiff plastic or non metallic brush If a metal brush is used its size should be slightly smaller than the flue to avoid damaging the chimney Do not use a brush that will scratch the stainless steel interior of the chimney 3 Do not expect chemical cleaners to keep your chimney clean The rain cap can be removed for inspection a...

Page 16: ...ssed air through the combustor Try to clean the combustor with any sharp tool Cleaning Procedure 1 Rotate the retainers to release the combustor support plate while holding it to make sure it does not drop 2 Rotate the support plate and remove the combustor 3 Remove fly ashes on the combustor using a soft brush 4 Put the combustor back in place Figure 3 3 3 5 Doorframe Care Use a glass cleaner and...

Page 17: ... Remove the left side refractory brick 4 Remove the right side refractory brick 5 Remove the back refractory brick To install the new refractory bricks follow the above steps in reverse Figure 4 3 3 8 Door Installation The door must be installed only when the installation of the BIS PANORAMA is completed All you have to do is fit the male part of the hinge already fixed on the door in the female p...

Page 18: ...g conditions If the BIS PANORAMA is operated continuously with the combustion air damper closed the glass will tend to get dirty unless the fuel firebox and glass are maintained at hot temperatures see Refuelling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorised Security Chimneys International dealer can recommend a suitable cleaner which is ...

Page 19: ...15 Around ash trap 8 2 wide x 1 4 thick ...

Page 20: ...ireplace system Weights are given in the appendix Next measure the area occupied by the fireplace that is normally 38 X 24 _ Note the floor construction and consult your local building code to determine if additional support is needed 3 A minimum of 7 2134 mm measured from the floor to the ceiling is required to install the BIS PANORAMA The appliance can be installed on a combustible floor or on a...

Page 21: ...tension Requirements The fireplace can be installed directly on a combustible floor Combustible floor in front of the fireplace must be covered with tile marble stone or any other non combustible material fig 7 Figure 7 ...

Page 22: ...ame the fireplace with vertical studs at the sides of the fireplace running from floor to ceiling see figure 8 If combustible facing is to be used position the studs back from the front edge of the fireplace a space the thickness of the facing material so that the facing can be installed flush with the fireplace facing Frame headers between the vertical studs only as follows Place 2 x 3 or 2 x 4 h...

Page 23: ...19 Figure 10 Figure 11 ...

Page 24: ...20 INSULATED CHASE CONSTRUCTION Figure 12 ...

Page 25: ...pace delimited by the width of the unit 38 and a height of 54 from the base of the appliance Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing figure 14 Mantel The mantel must be installed at least 54 1372 mm above the base of the fireplace figure 13 The shelf may be lowered to 48 inches if the upper panel is blocked by ...

Page 26: ...22 Figure 15 ...

Page 27: ...sulation strip is installed inside c The fireplace façade can be covered with non combustible material fig 18 The safety rules for hot air ducting gravity kit installations are the following Minimum height 68 1727 mm Maximum length See figure 17 The height of the louver must be measured from the base of the BIS to the middle point of the louver When installing the double outlet system the hot air ...

Page 28: ...24 ...

Page 29: ...25 Figure 17 Figure 18 ...

Page 30: ...5 When traversing a combustible wall or floor a firestop must be installed at the wall or floor penetration The hole size must be 13 X 13 330 mm x 330 mm 6 Do not connect the hot air ducts to a central heating system Malfunction of the heating system s fan will cause the fireplace to overheat A furnace duct is only single wall and not double wall as is required for the BIS PANORAMA hot air exhaust...

Page 31: ...act with the fireplace 3 Route the flexible pipe to the chosen location The ducting system can be installed either in an upper room or in a lower room 4 Attach the flexible pipe to the fan using the collars figure 20 5 Fix the decorative grill fan adaptor to the fan 6 Attach a standard 3 x 10 grill to the adaptor 7 Install the blower thermostat in that part of the house to be heated by the hot air...

Page 32: ...ow or exposed to extreme wind and well away from automobile exhaust fumes gas meters and other vents 5 The duct and register may be installed above or below floor level 3 6 1 Outside Air Installation Make a 4 _ 110 mm hole in the outside wall of the house at the chosen location From outside place the outside air register in the hole open side down and fasten the register to the wall with screws as...

Page 33: ...very 2000 feet 600 m above sea level 5 All chimney installations must include at least one support The maximum chimney length that can be supported by the fireplace is 9 ft 2 75 m for Secure TempS2100 Nova TempHT6000 12 ft 3 7 m for Secure TempASHT Nova TempHT6103 and 20 ft 6m for ACBI chimney 6 The chimney must extend at least 3 ft 915 mm above its point of contact with the roof and at least 2 ft...

Page 34: ...e first chimney length on the fireplace To lock it in place turn _ of a turn clockwise With the ACBI chimney you must use a starter section before installing the first chimney length figure 28 Continue installing chimney lengths making sure to lock each length in place 4 Every time the chimney passes through a ceiling or a wall install the appropriate firestop When you reach the desired height ins...

Page 35: ...31 Figure 26 Figure 27 ...

Page 36: ...32 AC CHIMNEY INSTALLATION AIR COOLED GALVALUME CHIMNEY Figure 28 NOTE THE OUTSIDE AIR KIT IS MANDATORY FOR BOTH FIREPLACE AND CHIMNEY ...

Page 37: ... 7 7 0 13 3 8 340 mm 15 1 8 384 mm 15 380 mm 2 12 13 5 8 345 mm 15 3 8 390 mm 15 3 8 390 mm 4 12 14 1 8 359 mm 16 406 mm 16 1 8 410 mm 6 12 15 380 mm 17 432 mm 16 7 8 430 mm 8 12 16 1 8 410 mm 18 1 4 465 mm 18 1 4 465 mm 10 12 17 1 2 445 mm 19 3 4 502 mm 19 5 8 500 mm 12 12 19 483 mm 21 3 8 545 mm 21 3 8 545 mm CROSS SLOPE HOLE SIZE ACBI CHIMNEY ...

Page 38: ... vertically Secure the elbow using three 3 _ 12 mm screws provided with the elbow 4 Use a plumb bob to line up the centre of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to page 28 5 From below install a firestop See figure 26 6 A support ST or SO must be used on the first 15 section 5 m 7 Continue with the regular installation ACBI Chimney...

Page 39: ...HS BETWEEN ELBOWS CHIMNEY 7 ELBOW DEVIATION LENGTH 8 12 18 24 36 48 8 36 36 48 24 48 36 48 48 48 DEVIATION 3 5 16 4 5 16 5 7 8 7 7 16 10 _ 13 5 8 15 _ 16 _ 18 1 16 19 5 8 22 _ 25 13 16 15º LENGTH 16 19 7 8 25 11 16 31 _ 43 1 16 54 5 8 61 7 16 65 _ 71 1 16 76 7 8 88 _ 100 1 16 DEVIATION 7 3 8 9 3 8 12 3 8 15 3 8 21 3 8 27 3 8 30 7 8 32 7 8 35 7 8 38 7 8 44 7 8 50 7 8 Secure TempS2100 Nova TempHT600...

Page 40: ...36 Figure 31 Figure 32 ...

Page 41: ...ate locations we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 CHIMNEY 7 dia ANGLE HOLE SIZE 30º 340 mm x 845 mm 13 3 8 x 33 _ Secure TempASHT Nova TempHT6103 45º Canada only 340 mm x 591 mm 13 3 8 x 23 _ 30º 380 mm x 972 mm 15 x 38 _ Secure TempS2100 Nova TempHT6000 45º Canada only 380 mm x 657 mm 15 x 25 7 8 ACB...

Page 42: ...mney a support section ACBI7SL must be used every 30 ft 10 m or the universal support AC10SU every 20 ft For roof support installation refer to the instructions provided with the support UNIVERSAL OFFSET SUPPORT This support is used to support the chimney above an offset When the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney The maximum heigh...

Page 43: ...t their terminations be separated by at least 16 410 mm horizontally and 18 460 mm vertically This separation is to prevent smoke migrating from one chimney to another see figure 34 Figure 34 4 7 CHIMNEY ADAPTOR Secure TempS2100 Nova TempHT6000 The fireplace is normally supplied with a chimney adaptor suitable for the Secure TempASHT Nova TempHT6103 chimney If you want to install a Secure TempS 21...

Page 44: ...its location Temporarily install the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 45º or 30º 3 Increase the size of the hole until a 45º or 30º Tubinox liner elbow can be easily slipped through 4 Slide the liner down from the top of the m...

Page 45: ...BF Radiation shield ACBI7RS Attic radiation shield ACBI7RSA Insulated wall radiation shield 30º AC10RSMI30 Outside air kit chimney AC ZI flex insulation outside register and coupling Flat roof flashing ACBI7FR Adjustable Roof Flashings 1 12 7 12 5º 30º ACBI7FAR 8 12 12 12 30º 45º ACBI7FBR Storm collar AC10FC PARTS AND COMPONENTS LIST Fireplace Description Part No Victorian arch shape door gold pla...

Page 46: ...rol for BISZY VTU Thermostat 24V kit heating and cooling HCTW Back draft damper BISBD Adaptor for fan to flexible pipe BISAVF Other Options Cast iron corner ornaments with magnets APPC 01 Cast iron corner ornaments with magnets APPCS 02 Cast iron top ornament with magnet APP 03 Panel for clean face option BPCF Heat activated on off pre wired fan kit UZY3 Masonry chimney adaptor BISPMA 7 APPENDIX S...

Page 47: ...30B2CF01 Ash tray kit PR B2GA1 Ash tray PR BISUZH Fireplace top PR SR2432 Fireplace left side PR SR2435 Fireplace right side PR SR2434 Fireplace back PR SR2436 Touch up paint Forrest Paint Metallic Black SBMB6309 Wooden handle door PR SR1787 Wooden handle by pass PR SR2072 Rod and lock PR SR2118 Ceramic glass panel Victorian door PR SR2107 Glass gasket PR SR1823E Door gasket PR SR1823D Hinges set ...

Reviews: