8
LUBRICATION
The Slicer Product Pusher Feed Screw will need to be lubricated periodically using the Haynes Spray
U.S.P. Light Duty Sanitary Lubricating Spray. The Spray is Light, Tasteless, and colorless, odorless oil.
NSF (National Sanitation Foundation) rated H1. U.S.D.A. rated H-1. All ingredients are FDA approved.
It is necessary to lubricate the Feed Screw with the Spray weekly or when excessive drag is felt.
1. Always turn “OFF” the Slicer, Disconnect the Power Cord (Unplug Power Cord from the Electrical Outlet).
2. Open the Load Chamber Cover. Between the top Cover and the Loading Chamber wall locate the
Feed Screw between the Slot
3. Spray the Feed Screw Lightly, the entire length.
4. Pull the Product Pusher Handle Release together and move the Product Pusher back and
forth several times.
5. Wipe off excess oil.
Summary of Contents for 109PCM
Page 2: ......
Page 4: ......
Page 14: ...10 109PCM ELECTRICAL DIAGRAM ...
Page 15: ...11 ...
Page 26: ...22 ...
Page 28: ...24 CONVEYOR OPTION WIRING DIAGRAM ...
Page 30: ...26 OPERATOR S NOTES ...