RF Directional Thruline® Wattmeter Model APM–16
24
Specifications
Frequency Range (Element Dependent)
2 MHz – 2.3 GHz
Power Range (Element Dependent)
1 W – 1 kW
Impedance, Nominal
50 ohms
VSWR, Insertion
1.05:1 max 2 MHz – 1 GHz
Accuracy
10° to 35°C
–20° to +50°C
± 4% of reading ± 1% of full scale
± 6% of reading ± 2% of full scale
Peak/Average Ratio
> 10 dB
Settling Time
< 1 s
Meter
Shock mounted linear scale with expanded
scales of 25, 50 and 100 full scale. Includes
5% overrange.
Connectors
Bird “QC” N Female normally supplied
Battery
Standard 9V battery. 200 hours operation,
minimum.
Operating Position
Any
EMC
Complies with 89/336/EEC and 92/31/EEC
Emissions Immunity Safety
EN 55011:1991 Class B
EN 50082-2:1995
EN 61010-1:1993 in accordance with 79/23/
EEC and 93/68/EEC
Complies with IEC-1010-1,
UL-1244, and CSA-231
Temperature, Operating
–4 to +122 °F (–20 to +50 °C)
Temperature, Storage
–13 to +149 °F (–25 to +65 °C)
Humidity
90% noncondensing max
Dimensions (Nominal)
3-5/8”L x 4”W x 6-7/8”H
(92 x 102 x 175 mm)
Weight (Approx.)
4 lb. (1.8 kg) with N-Connectors
Finish
Black Powder Coat