Bird Technologies
26
Battery Procedures
Testing the Batteries
The Model 4314B Thruline Wattmeter uses two 9 V alkaline batteries to
supply power for the peak circuitry.
1. Set the ON/BATTERY switch to the BATTERY position.
Note:
The meter pointer should travel to the right of the
“BAT.TEST” mark.
2. If the pointer stops below the mark, replace the batteries.
Replacing the Batteries
1. Remove the back cover by unscrewing the four 8-32 Phillips flat
head screws.
Note:
The screws are located two on each side of the meter
housing near the back edge at the top and bottom of the sides.
2. Pull the cover straight off.
3. Rotate the battery in its clip, then pull upward freeing the battery.
4. Remove the snap-on battery connector.
5. Insert the battery into the clip and replace.
6. Repeat above procedure for the other battery.
Figure 9 Replacing the Batteries
Inside Back
+
Summary of Contents for 4314B
Page 2: ......
Page 10: ...viii...
Page 20: ...Bird Technologies 8 Figure 3 Model 4314B Schematic Diagram...
Page 22: ...Bird Technologies 10...
Page 31: ...Operating Instructions 19...
Page 34: ...Bird Technologies 22...
Page 46: ...Bird Technologies 34 Figure 13 Replacement Parts Inside Back 1 2 3 4 5 6 7 8 9...