background image

4

3x

OK?

OK?

Designed in Switzerland / Made in China

BBC Bircher Smart Access, 

BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com

1

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

1 2

2

1

2

1

1 2

2

1

1 2

*

*

*

LED 

LED 

LED 

8

Trouble shooting

9

Technical data

10

EU Declaration of Conformity

12

Contact

8.1   Warning indicator for low battery voltage

8.2   Errors (see 7.1)

To find out which transmitter 
has low battery voltage: 
Press each edge. 

To find out which 
transmitter causes 
error indication: 

Every minute

Battery good

Battery bad

Receiver

Supply voltage

12–36 V DC
12–36 V AC, 48–62 Hz

Power consumption

max. 1.0 W

Safety outputs (2 x 2 relays) max. 36 V AC/DC; 1 A (NC with 1A fuse)
Output battery low (SSR)

max. 36 V AC/DC; 0.1 A

Input stat. sensors

Sensors with 8.2 kOhm resistor

Test input

max. 36 V DC; 36 V AC, 48–62 Hz 
max.11 mA 
Uth > 10 V AC/DC

Antenna connection  
(optional)

SMA (f)

Number of supported 
sensors

max. 14  
(stationary sensors included)

Mounting

DIN-rail

Protection class IEC 60529

IP20

System

Operating frequency

868.3 MHz

Reaction time

Typ. 15 ms

Range

60 m (at optimal condition)

According to EN ISO 13849-1

PLd  
for Cat. 3 applications 
+ test input for Cat. 2 applications

Operating temperature

–20 °C to +60 °C

Beep

Beep

Beep

See attachment

11

WEEE

Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of  
the respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.

7.2  Menu structure

Level 3:  

Stationary edges

Level 2:  

Bircher signal 

indicator (BSI) 

Level 1:  

Pairing

Level 4:  

Test input

Entry 

Exit

Long press  

joystick

Press  

joystick

Press  

joystick

Press  

joystick

Press  

joystick

IN1 to output 1

IN2 to output 2

to output 1 + 2

High active

IN2 to

output 2

to

output 2

IN1 to 

  output 1

to 

  output 1

none

clear (5 sec.)

Low active

default setting

Red

Stays red

Flashes orange

or

or

Transmitter good

Transmitter with error

Details see 

supplemen-

tary sheet

Summary of Contents for XRF-RD

Page 1: ...ternational regulations safety standards codes and laws as well as the Machinery Directive 2006 42 EC should this apply Always consider the safety functions of your applications as a whole never just in relation to one individual section of the system The installer is responsible for testing the system to ensure it meets all applicable safety standards Safety devices that are classified as Categor...

Page 2: ...r Receiver Receiver Receiver Receiver Receiver Transmitter Tx1 Transmitter Tx2 Transmitter s Release button Release button Release button Pair to output 1 Pair to output 2 Pair to both outputs Long press joystick Move joystick left Move joystick right Move joystick upwards Move joystick acc to requested configuration see 7 2 LED LED LED LED LED LED LED LED Flashes orange Orange Orange Orange Flash...

Page 3: ...ing edge orange 2 8k2 CLOSED CLOSED open open Stationary sensor 1 pressed output 1 orange 1 CLOSED open 8k2 CLOSED open Stationary sensor 2 pressed output 2 orange 2 8k2 CLOSED CLOSED open open Wicket door open XRF TW on channel 2 orange 2 8k2 CLOSED CLOSED open open Configuration a Pairing b BSI c Stationary edges d Test Input orange flashing 2 1 a 2 1 b 2 1 c 1 2 d CLOSED open CLOSED open open u...

Page 4: ... supported sensors max 14 stationary sensors included Mounting DIN rail Protection class IEC 60529 IP20 System Operating frequency 868 3 MHz Reaction time Typ 15 ms Range 60 m at optimal condition According to EN ISO 13849 1 PLd for Cat 3 applications test input for Cat 2 applications Operating temperature 20 C to 60 C Beep Beep Beep See attachment 11 WEEE Devices with this symbol must be treated ...

Reviews: