21
4. USING PRINTER
4.1 Power-on Utilities
There are three power-on utilities to set up and test hardware. These utilities are
activated by pressing the
FEED
or
PAUSE
button and turning on the printer
power simultaneously. The utilities are listed as below:
1. Self-test
2. Gap sensor calibration
3. Printer initialization
4.1.1 Self Test Utility
Install the label first. Press the
FEED
button and then turn on the printer power.
Do not release the
FEED
button until the printer f
e
eds labels. The printer
performs the following items:
1. Calibrate label pitch
2. Print out thermal print head check pattern
3. Print the internal settings
4. Enter dump mode
Regarding the self-test and dump mode, pleas e refer to section 3.5 "Self Test"
and section 3.6 "Dump Mode" for more information.
4.1.2 Gap Sensor Calibration Utility
This utility is used to calibrate the sens
i
tivity of gap sensor. Users may have to
calibrate the gap sensor for two reasons:
1. The media is being changed to a new type.
2. Initialize the printer.
Note: The ERR. LED may flash if gap sensor is not calibrated properly.
Please follow the steps below to calibrate gap sensor:
1. Turn off the printer power and install blank labels (without any logo or
character) on printer.
2. Hold down the
PAUSE
button then turn on printer power.
3. Release
PAUSE
button when the printer feeds labels.
Do not
turn off
printer power
until the printer stops and two green LEDs light on.
Note: Black mark sensor has fixed sensitivi
t
y. It is no need to calibrate the
black mark sensor