Press  the  MODE  button  to  select  WARM  or  WARM  and  UV  purification  mode.  The  “WARM” 
(“WARM” and “UV”) indicator will light up. The “HUM” indicator under HEATING button also light 
up as the unit gives warm air and humidity simultaneously. 

 

Press the HEATING button to select your desired warm air level; HIGH or LOW. 

 

Press the SPEED button to select your desired fan speed. 

 

Press OSCILLATE to select your preferred air flow direction, e.g. air swing from left to right, or 
fixed direction of air flow. 

 

Check  water  level  in  water  tank  during  operation.    Once  water  below  minimum  level,  turn  off 
power button and Main Power  Switch.    Then refill  the water  tank with  fresh water in  the tank.   
Please refer to procedures to fill up water tank. 

 

To turn off the unit, press the POWER button again.    If you do not intend to use the product for 
some time also turn off the Main Power Switch after the product has stopped.    Empty the water 
tank after turning off the Main Power Switch. 

 

NOTE: 

 

This unit is built with Automatic Humidistat Control. You can set your desired RH% (Relative Humidity 
%) by pressing the HUMIDITY button. The adjustable range is from RH 30% to RH 70%. The RH% will 
be adjusted in unit of 5%.   
 
When  the  room  RH  (Relative  Humidity)  has  been  brought  up  to  your  set  RH%,  the  unit  will  stop 
humidifying function.    When the room RH% drops below your set RH%, the unit will restart humidifying 
function automatically. Air washer function is working whenever water is pumping through the system.   
 
If you do not set RH%, the unit is preset at RH 50%. The adjustable range is RH 30% to RH 70%. 
 
Humidifying  is  suggested  for  use  while  the  RH%  is  below  20%  as  such  low  humidity  level  can  be 
unhealthy and uncomfortable. The recommended humidity level is 40% to 50%. This unit gives a cool, 
invisible moisture output. It is normal not to see the mist. 

 

TIMER OPERATION 
 

 

The Timer can be used to switch the unit off after a selected number of hours. 

 

Select the desired operating mode. 

 

Press the TIMER button once and the unit will switch off after 1 hour.    Press the button again for 
2 hours, again for 3 hours etc.    The maximum timer setting is 8 hours. 

 

To cancel the Timer setting press the TIMER button again until all the timer indicators light off. 

 

OSCILLATE OPERATION 

 

 

Press the OSCILLATE button to start the louvers moving from side to side.    This will improve the 
distribution  of  the  cooled  or  warmed  air  in  the  room.    To  stop  the  oscillation,  press  the 
OSCILLATE button again until indicator light off. 

 

You  can  change  the  air  direction  (up  or  down)  by  manually  adjusting  lever  alongside  the 
horizontal louvers. 

Summary of Contents for EHUV-10-03

Page 1: ......

Page 2: ...URE REFERENCE SECTION PAGE 1 BEFORE INITIAL USE 2 2 INTRODUCTION 3 3 RECOMMENDED USE 3 4 TECHNICAL SPECIFICATIONS 4 5 PARTS 4 6 SAFETY RULES 5 7 OPERATION 7 1 Control Panel 7 7 2 Operation 9 7 3 Opera...

Page 3: ...on back of product Date of Purchase Attach your ORIGINAL Purchase Receipt here Your receipt is your proof of Purchase and is necessary for Warranty service ATTENTION Check the box and the packaging f...

Page 4: ...hree speed fan with swing air The active carbon dust filter reduces dust pollen and odors year round is a true year round solution All functions may be controlled by the included remote control For th...

Page 5: ...e Removable water tank capacity 25 pints Filter material Honeycomb Net Weight 20 9 lbs 5 PARTS 1 Handle 9 Remote control storage position 2 Left side panel 10 Rear 3 Power cord 11 Top ice compartment...

Page 6: ...th a damaged cord plug after the appliance malfunctions or has been dropped or damaged in any manner 10 Do not use outdoors 11 Do not let cord hang over the edge of a table or counter or let it touch...

Page 7: ...amp is harmful to eyes and skin Do not operate the appliance if there is any damage to the protective covering of the lamp Do not operate if any light is showing from UVC lamp 22 Replace the UVC bulb...

Page 8: ...each mode Cool mode with LED indicator Cool mode UV purification with LED indicator UV LED indicator Warm mode with LED indicator Warm mode UV purification with LED indicator UV LED indicator Fan only...

Page 9: ...or light on air swings from left to right Press again for fixed direction air flow the indicator will light off HEATING WARM When the unit is set to WARM mode the HUM indicator on HEATING button light...

Page 10: ...ill appear on the LED display The operation range for RH is 30 to 70 If you do not adjust the RH the unit is preset at 50 Air washer system is working when water is pumping Press the SPEED button to s...

Page 11: ...e RH will be adjusted in unit of 5 When the room RH Relative Humidity has been brought up to your set RH the unit will stop humidifying function When the room RH drops below your set RH the unit will...

Page 12: ...model no EHUV 10 03 Only remove the tank when the water level is low and wipe out any residual pollutants with a damp cloth before re filling The water tank can be filled several different ways NOTE O...

Page 13: ...have the water tank back in place press firmly until you hear it lock in If you do not hear the click and if the back of the tank is not flush it will not operate make sure the tank is locked in plac...

Page 14: ...move the batteries if the unit is not going to be used for an extended period of time Function Keys on Remote Control Remote control colour should be silver in this model no EHUV 10 03 ON OFF Press th...

Page 15: ...in the original packaging in a dry dust free area during off season usage The life of the UV is 1 year after that the efficient of the UV lamp decrease Replacing the UV lamp See the below picture to...

Page 16: ...lem Commercial de scaling de mineralizing PH balancing and water softening are widely available As these issues are highly regionalized please consult a local water company or pool supply company how...

Page 17: ...gallons of water DO NOT PUT IN DISWASHER Soak the filter overnight and then thoroughly rinse with cool clean water If after cleaning and rinsing the filter still has scaling or other mineral build up...

Page 18: ...l After several use the water color will be clean Noise of water pump when water not up to min water level Turn off the product Add water and then turn on the product again Abnormal noise inside the p...

Page 19: ...will be released If the product is out of the warranty period or determined that it was abused or not operated properly you will be charged for the freight to the BIP return center The BIP customer se...