Power and “Lamp Life” RESET
1.
The ON/OFF button switches the device:
a.
ON - Standard Mode (Unit power on, light indicators on)
b.
ON - Night Mode (Unit power on, Power Indicator LED intermittently Flashes
green)
c.
OFF (Unit power off)
2.
The Power light shows whether the device is powered and operating normally and
also indicates when the accumulated lamp life reaches 8,760 hours (1 year) and
needs replacement. The Power LED has the following modes:
O P E R AT I O N
(Continuous Loop)
ON - Standard Mode
ON - Night Mode
OFF
OFF
ON - Night Mode
ON - Standard Mode
3.
Steady green: normal operation
Green flash: night mode
Flashing red: contact BioZone for service
Steady red: replace lamp
Whenever a new UV lamp is installed, the “Lamp Life” RESET button MUST be
pressed to reset the timer within the microcontroller to 8,760 hours. The timer will
only register lamp life while the unit is powered on.
a.
When the new UV lamp is installed correctly and “Lamp Life” RESET is
pressed, the Power light will flash 2 times in red color then turn to green
color and begin to operate normally.
b.
If the red light keeps flashing, it indicates that the “Lamp Life” RESET button
has not been pressed. Re-install the UV lamp and press the “Lamp Life”
RESET button until the Power light turns to green color.
4.
The ON/OFF button controls the cycle of the operation. The control sequence is in the
following manner: