5. Operation Mode, Dehumidifying / Temperature Control
The controller can be used in two operation modes;
-
Dehumidifying Control
-
Temperature Control
These modes of operation can be changed in the Installation Menu under “base adjustments “.
A seasonal change of the mode of operation is problem-free (e.g. Winter garden).
This can be done in the “Base Menu”, to get there you need to press the red button with the
gears symbol
5.1 Adjustable values
•
Date and Time
•
Opperation Mode
•
Running Time
•
Pause Time
•
Running Time (From on-time to off-time)
•
Minimum Dampness Inside
•
Freeze Protection Mode (on/off)
•
Freeze Protection Temperature
•
Switching Limit Inside/outside
•
Upper Temperature Threshold (Temperature Control)
•
Forced Ventilation
6.
Buttons / Display
Die keypad consists of;
•
Up, down, left and right arrow keys (blue)
•
OK-Button (green)
•
Basic-Settings-Button (red)
The 4-line LED display, shows all necessary data.
In the operation status you can scroll through the
different menu displays by pressing the
right and left arrow keys
As soon as you see a cursor flash, you can change
the value by pressing the up or down arrow keys.
The displayed value is the actual current set value.
After you have changed/set the values to your requirement, you can continue scrolling through
the menu displays.
9
temperature
inside: 21,8 °C
outside: 14,3 °C
fan: active
parameter
frost protection
state: ON
Temp. min.: 5°C