TROUBLE SHOOTING
CAUTION: DO NOT OPEN THE SIDE PANEL WITHOUT FIRST TURNING OFF POWER
TO THE MACHINE.
*. Feeder do not start
- Breaker off
- Machine unplugged
- Switch is off
- Bowl full
- Fuse Blown
*. No water but powder and
- No water going to feeder (faucet shut, etc.)
Agitator motor working
- Concentration knob turned clockwise all the way
- Valve filter dirty
- Inlet valve defective (replace)
*. Mixing bowl filled with powder
- Same as above
*. A small amount of water
- Concentration knob turned clockwise all the way
Flowing into bowl
- Check water supply
*.
No powder but water and
- Powder switch on rinse
Agitator motor working
- Powder motor stuck
-
Auger unhooked
- Powder motor defective (replace)
*. Mixing motor not working
- Mixing motor dirty
- Computer Controller (replace)
- Mixing motor defective (replace)
*. Mixing motor does not stop
- Computer Controller (replace)
*. Milk overflows, feeder does not
-Too much water turn concentration knob down
Stop
- Computer Controller (replace)
*. Water too warm
- set thermostat to 40øC
- Thermostat out of order (replace)
*. Water does not heat up
- set thermostat to 40øC
- heating element burned up (replace)
Revised 4-21-17