Error Code:
!
All functions are suspended.
Error Message: iEOG water refilling timeout
Note: Refer instructions in Section 3.5 for “Re-Start” procedures.
Error Code:
!
All functions are suspended.
Error Message: System temperature found too high (>44°C).
Note: Refer instructions in Section 3.5 for “Re-Start” procedures.
CAUSE
SOLUTION
Low Pressure
Correct input water pressure and then re-start the unit.
iEOG Pre-filter
jammed
Clean or replace as needed and then re-start the unit.
Others
Contact your BioSure dealer or service provider for service.
CAUSE
SOLUTION
High Ambient
Temp.
Correct ambient temperature or enhance on-site air-cooling
performance and then re-start the unit.
Bad fan(s)
Contact your BioSure dealer or service provider for service.
26