40 | Chapter 4: Useful help
RAID 10 combines the advantages (and
disadvantages) of RAID 0 and RAID 1 in one
single system. It provides security by mirroring
all data on a secondary set of disks (disk 3 and
4 in the drawing below) while using striping
across each set of disks to speed up data
transfers.
Features and Benefits
• Drives: Minimum 4, and maximum is 6 or 8, depending on the platform.
• Benefits: Optimizes for both fault tolerance and performance, allowing for automatic
redundancy. May be simultaneously used with other RAID levels in an array, and allows
for spare disks.
• Drawbacks: Requires twice the available disk space for data redundancy, the same as
RAID level 1.
• Fault Tolerance: Yes.
A RAID 5 array can withstand a single disk
failure without losing data or access to data.
Although RAID 5 can be achieved in software,
a hardware controller is recommended.
Often extra cache memory is used on these
controllers to improve the write performance.
Features and Benefits
• Drives: Minimum 3.
• Uses: RAID 5 is recommended for transaction processing and general purpose service.
• Benefits: An ideal combination of good performance, good fault tolerance, and high
capacity and storage efficiency.
• Drawbacks: Individual block data transfer rate same as a single disk. Write performance
can be CPU intensive.
• Fault Tolerance: Yes.
Note
»
For more details settings about Intel® Rapid Storage Technology (Intel® RST), please visit
http://www.intel.com/p/en_US/support/highlights/chpsts/imsm
»
PCI-E Storage only supports RAID 0, 1 & 5.
»
SATA RAID only supports UEFI Mode.
Summary of Contents for B365GTQ
Page 6: ...6 Chapter 1 Introduction 1 5 Motherboard Layout Note represents the 1st pin...
Page 47: ...FCC FCC 15 Class B BIOSTAR BIOSTAR BIOSTAR CE 2004 108 CE 2006 95 CE 1999 05 CE...
Page 49: ...3 B365GTQ 1 1 0 45 1 2 Serial ATA x2 ATX I O x1 x1 x1...
Page 52: ...6 1 5 1...
Page 53: ...7 B365GTQ 2 1 CPU 1 CPU CPU 2 3...
Page 54: ...8 4 CPU CPU 5 CPU LGA1151 CPU CPU CPU CPU...
Page 55: ...9 B365GTQ 2 2 1 CPU CPU CPU 2 2 CPU CPU CPU CPU...
Page 69: ...UEFI BIOS 23 B365GTQ eHot Line eHot Line Send Send Do Not Send Save As...
Page 71: ...UEFI BIOS 25 B365GTQ RACING GT EVO Utility RACING GT EVO RACING GT EVO 1 2 3 4...
Page 73: ...UEFI BIOS 27 B365GTQ GT Touch Windows RACING GT EVO ECO 1 2 3...
Page 75: ...UEFI BIOS 29 B365GTQ LED LED LED LED LED LED 9 VIVID LED DJ LED LED...
Page 77: ...UEFI BIOS 31 B365GTQ 1 CPU 2 3 CPU...
Page 78: ...32 UEFI BIOS 1 2 3 Default 4 5 6 CPU CPU...
Page 79: ...UEFI BIOS 33 B365GTQ Racing GT EVO Utility...
Page 84: ...38 4 5 RAID RAID Block 2 6 8 Uses RAID 0 RAID 1 2 RAID 1 RAID1 RAID 2 2 RAID 1 100 2...