background image

 

                            

 

 

Prox-E Installation Guide v1.2|10.2018|en 

 

Safety Instructions 

Safety instructions must be followed in addition to International Standards (ISO/IEC)

*

, and other safety 

regulations. 

 

Caution

 

Caution indicates a hazard with a low level of risk which, if not avoided, could 
result in minor or moderate injury. 

 

Note

 

Note indicates an 

important

 remark, which should be taken into attention. 

 

 

Caution

 

General requirements:

 

 

Read, follow and retain instructions – All safety and operating instructions 
must be read and followed properly before putting the unit into operation. 

 

Do not turn on the power supply until all installation procedures are 
finished 
– this may lead to injury or equipment damage.  

 

Do not disconnect or connect cables while unit is powered on – this may 
lead to unit malfunction and software errors. 

 

Do not expose unit to heat or fire – high temperature impact may lead to 
case deformation and circuit board damage.  

 

Make sure that all cables and screws are fastened properly - otherwise 
case damage or circuit shortcut may happen

 

Note

 

Additional requirements:

 

 

Use a clean, dry cloth to remove any dirt or dust from the unit. 

 

 

 

 

 

 

*IEC 60204-1: Safety of machinery – Electrical equipment of machines. (Part 1: General requirements) 

 

Summary of Contents for Prox-E

Page 1: ...BioSmart Prox E Installation Guide www biosmart tech com...

Page 2: ...eneral installation notes 8 Mounting on wall 8 Mounting on DIN rail 9 Power supply connection 10 Network connection 10 BioSmart Readers connection 11 Fail safe lock connection with external power supp...

Page 3: ...owed properly before putting the unit into operation Do not turn on the power supply until all installation procedures are finished this may lead to injury or equipment damage Do not disconnect or con...

Page 4: ...t BS RD and BioSmart Mini readers Controller is compatible with BioSmart Studio software version V5 0 3 269 and above Specifications Number of users 30 000 Logged events 100 000 Number of time groups...

Page 5: ...2018 en Part names and functions Name Description Alarm LED Alarm indication Work LED Work mode indication Mounting screw Fastens front cover Mounting holes Suited for fixing screws Cable inputs Detac...

Page 6: ...ackage contents Item Number pcs BioSmart Prox E Controller 1 Mounting kit four 6 35 dowels four 3 5 38 self tapping screws 1 Opening the case Remove the front cover retaining screw Detach the cover fr...

Page 7: ...gs reset BOOT Jumper Boot mode VL1 Opto isolator Controls case opening Connector names and description Name Description Used for 1 GND Power supply ground Power supply 2 12V 12V Power supply Power sup...

Page 8: ...red indicator output 24 WI01 Wiegand input 01 Reader wiegand 00 25 WI11 Wiegand input 11 Reader wiegand 01 26 SP1 Reader speaker input Reader speaker output 27 L_G1 Reader green indicator input Reader...

Page 9: ...Four twisted pair cables of no lower than category five with a wire size of no less than 0 2 mm2 General installation notes Install the controller on vertical surface Cables must be installed in acco...

Page 10: ...ttons if needed according to p 2 5 2 11 Put cables through previously made holes 6 Attach the covering and fix the retaining screw Mounting on DIN rail 1 Place the lower clip on the edge of the rail 2...

Page 11: ...um of 1 500 mA which has obtained the approval of IEC EN 60950 1 See recommended cable type and maximum length of the cable in Cable types table Network connection See recommended cable type in Cable...

Page 12: ...pe in Cable types table Note Prox E supports up to four readers Caution Avoid star type topology when connecting readers Unique address should be provided for each reader Addresses are set using switc...

Page 13: ...ternal power supply See recommended cable type in Cable types table Install a diode as it shown on figure to protect controller relay from reverse current Use 1N4007 diode 1000V 1A or similar Use sepa...

Page 14: ...ternal power supply See recommended cable type in Cable types table Install a diode as it shown on figure to protect controller relay from reverse current Use 1N4007 diode 1000V 1A or similar Caution...

Page 15: ...1N4007 diode 1000V 1A or similar Use separate power supplies for lock and controller Caution Make sure K4 jumper is off Fail secure lock connection without external power supply See recommended cable...

Page 16: ...15 Prox E Installation Guide v1 2 10 2018 en Exit buttons and door sensors connection See recommended cable type in Cable types table...

Page 17: ...16 Prox E Installation Guide v1 2 10 2018 en Wiegand output connection See recommended cable type in Cable types table...

Page 18: ...17 Prox E Installation Guide v1 2 10 2018 en Wiegand input connection See recommended cable type in Cable types table...

Page 19: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com...

Reviews: