23
less than 2 ½ inches tall if mounting into dry wall so that there is
enough material to hold the anchor. The recommended size is 3 ½
inches wide by 2 ½ inches tall.
f.
For V-Station, the rear of the unit will protrude past the wall plate
and into the wall approximately 1 inch (depending on the
Weidmuller connectors attached). The access hole must be exactly
the size of the hole in the wall plate (136mm (~5 3/8”) wide by
69mm (~2 ¾”) tall). It may be helpful to trace the edges of the hole
in the wall plate in pencil before cutting.
g.
Please see pages 26 – 28 for templates for the single-gang and
double-gang mounting plates
. These templates are dimensioned in
millimeters (mm).
3.
Make pigtail (or Weidmuller for V-Station) wiring connections to power,
Wiegand or other connections prior to mounting wall plate.
4.
For the V-Smart, feed pigtail cable from Smart Card Module through hole
in wall plate from the front and connect to pigtail cable already wired in
wall cutout.
5.
For the V-Smart, connect Smart Card Module to wall plate. Line up four
tabs, push forward and then down. Secure smart card module with the
security screw at the bottom.
6.
Feed main pigtail DB15 connector (not applicable to V-Station) through
wall plate from the back and proceed to mount wall plate:
a.
Optionally mount to a gang box using #6-32 screws provided.
b.
Optionally mount on wall.
i.
Use 4 outer mounting points (6 for V-Station).
ii.
Up to #6 screws can be accepted (screws and drywall anchors
are provided).
c.
Use template provided to mark holes.