BIOPAC Systems B-ALERT X10 User Manual Download Page 25

no

 

event

 

be

 

liable

 

to

 

Purchaser

 

or

 

to

 

the

 

Purchaser’s

 

customers

 

for

 

any

 

incidental

 

or

 

consequential

 

damages,

 

loss

 

of

 

use

 

or

 

other

 

commercial

 

loss,

 

however

 

occasioned.

   

 

ADVANCED

 

BRAIN

 

MONITORING,

 

INC.

 

MAKES

 

NO

 

WARRANTIES,

 

EXPRESSED

 

OR

 

IMPLIED,

 

INCLUDING

 

WITHOUT

 

LIMITATION,

 

WARRANTIES

 

OF

 

MERCHANTIABILITY,

 

FITNESS

 

FOR

 

PARTICULAR

 

PURCHASE

 

OR

 

PERFORMANCE

 

CHARACTERISTICS,

 

EXCEPT

 

TO

 

THE

 

EXTENT

 

SET

 

FORTH

 

HEREIN.

 

E.

 

Returns

 

and

 

Service

 

 

The

 

solid

state

 

circuitry

 

within

 

the

 

B

ALERT

 

X10

 

Sensor

 

Headset

 

requires

 

no

 

periodic

 

maintenance

 

or

 

calibration

 

other

 

than

 

long

term

 

battery

 

replacement.

   

For

 

the

 

Warranty

 

to

 

remain

 

in

 

effect

 

during

 

the

 

Warranty

 

Period,

 

all

 

repairs

 

must

 

be

 

performed

 

by

 

Biopac

 

Systems,

 

Inc.

   

Biopac

 

Systems,

 

Inc.

 

is

 

not

 

responsible

 

for

 

any

 

damage

 

resulting

 

from

 

service

 

work

 

performed

 

by

 

the

 

customer

 

or

 

its

 

representative.

   

All

 

returns

 

to

 

Biopac

 

Systems,

 

Inc.

 

must

 

include

 

a

 

Return

 

Merchandise

 

Authorization

 

(RMA)

 

obtained

 

by

 

calling

 

Customer

 

Support

 

at

 

(805)

 

685

0066.

   

Be

 

prepared

 

to

 

provide:

  

1)

 

your

 

name,

 

address,

 

and

 

telephone

 

number;

 

2)

 

the

 

Sensor

 

Headset

 

model

 

and

 

serial

 

numbers;

 

and

 

3)

 

an

 

explanation

 

of

 

the

 

problem.

  

The

 

Customer

 

is

 

responsible

 

for

 

all

 

shipping,

 

tariff

 

and

 

custom

 

costs

 

associated

 

with

 

the

 

return

 

or

 

repair

 

of

 

the

 

Sensor

 

headset.

   

 
 

F.

 

Trademark

 

Acknowledgements

 

 

B

Alert

 

is

 

a

 

registered

 

trademark;

 

B

Alert

 

Sensor

 

Headset

 

is

 

a

 

trademark

 

of

 

Advanced

 

Brain

 

Monitoring,

 

Inc.,

 

Carlsbad,

 

CA.

   

Synapse

 

is

 

a

 

registered

 

trademark

 

of

 

Med

Tek/Synapse

,

 

Arcadia,

 

CA.

   

All

 

other

 

products

 

or

 

brand

 

names

 

are

 

trademarks

 

or

 

registered

 

trademarks

 

of

 

their

 

respective

 

companies.

 

 
 
 

Copyright

 

©

 

2010

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

All

 

rights

 

reserved.

 

BIOPAC Systems, Inc.

 

 

B-Alert X10 User Manual

 

|       

25

 

 

Summary of Contents for B-ALERT X10

Page 1: ...User Manual 42 Aero Camino Goleta CA 93117 805 685 0066 http www biopac com Distributed by BIOPAC Systems Inc Manufactured by Advanced Brain Monitoring Inc...

Page 2: ...n 9 C Application 11 D Additional ECG Placements 14 E Ready to Collect 14 F Post session Clean up 15 A Common Headset and Sensor Issues 17 Chapter 4 Specifications 19 A B Alert X10 19 B Environmental...

Page 3: ...ons The Sensor Headset collects physiological signals from the sensors placed on the user sampling at 256 Hz The headset performs analog to digital conversion encoding formatting and transmitting of a...

Page 4: ...ation are required B ALERT X10 has no alarms classifications such as drowsiness There are only alarms for indications of excessive artifact Do not use the B ALERT X10 as a substitute for clinical ECG...

Page 5: ...on the EEG sensors as this will cause permanent damage and void the Warranty This device has been tested and found to comply with the limits for medical devices to the IEC 60601 standards These standa...

Page 6: ...MB virtual memory Windows XP or Windows 7 operating system NET framework version 3 5 installed Minimum of 50 MB hard disk space per 5 hour session One CD ROM drive VGA or higher resolution video adap...

Page 7: ...oam Sensors 12cc Syringe ECG Leads left Mastoid right Disposable Electrodes Synapse Gel Bottle Tube Cleaning Tools Tweezers Electrode Brush ABM USB Host device B Alert Dongle left Optional ESU MC righ...

Page 8: ...inimum 8hrs It takes 2 3hrs to fully charge a headset To recharge the Headset follow the steps below 1 Verify the Headset is in the off position Insert the X10 cable adapter into the sensor headset 2...

Page 9: ...rough each side of the Sensor Headset strap holders and fasten the Velcro Do this equally to both sides but leave loose for easy application to subject later c Verify that the Mastoid Leads are plugge...

Page 10: ...the foam and dispense gel You should see the gel begin filling the center of the foam ii The gel can also be dispensed into the foam from the sides by pushing the tip into either side of the foam unti...

Page 11: ...a snug fit c d Verify that the Neoprene Strap is centered on the subject and that it is not resting on the ears e While holding the strip in front of the subject with the foam pieces facing away from...

Page 12: ...subject s head while maintaining the correct alignment on the scalp g h h i Verify that all sensor sites are contacting the head and adjust straps if necessary j j Gently plug connector on the back o...

Page 13: ...4 Mastoids and ECG Leads BIOPAC Systems Inc B Alert X10 User Manual 13...

Page 14: ...thing or muscles which can compromise signal integrity Contact BIOPAC for additional information on alternative ECG placement E Ready to Collect 1 Plug in the USB Host Device B Alert Dongle or ESU to...

Page 15: ...the number of obstructions and avoid metal objects in the line of sight of the head and host units F Post session Clean up 1 Removal of Sensor Headset and Electrodes BIOPAC Systems Inc B Alert X10 Use...

Page 16: ...timal recordings clean the strip immediately after use Do not reuse foam sensors Strips are recommended for 25 30 uses Do not aggressively scrub the Sensor pads when cleaning If Sensor pad is removed...

Page 17: ...ensor Issues The following topics describe critical troubleshooting methods to undertake when encountering problems during the setup session of a subject Hands should be away from Face Part thick hair...

Page 18: ...Systems Inc B Alert X10 User Manual 18 NOTE The recommendations are not necessarily listed in a logical sequence Use best judgment to determine which trouble shooting tips are most relevant to the pro...

Page 19: ...either EEG or EOG Resolution 16 bit Bandpass Characteristics 0 1 Hz and 65 Hz at 3dB attenuation obtained digitally with Sigma Delta A D converter Noise 3 2 mV peak to peak out to 100 Kohms resistance...

Page 20: ...ration Transportation Storage Temperature 5o C to 40o C 41o F to 104o F 20o C to 70o C 4o F to 140o F 20o C to 70o C 4o F to 140o F Altitude 390 m to 3012 m 1254 ft to 9 882 ft 390m to 3012 m 1254 ft...

Page 21: ...he dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Page 22: ...determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol...

Page 23: ...nsmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Page 24: ...out regard or effect given to its or any other jurisdiction s conflicts of law jurisprudence D Product Limited Warranty The B Alert X10 Sensor Headset product is warranted to be free from defects in m...

Page 25: ...r any damage resulting from service work performed by the customer or its representative All returns to Biopac Systems Inc must include a Return Merchandise Authorization RMA obtained by calling Custo...

Reviews: