BIOPAC Systems B-ALERT X10 User Manual Download Page 24

 

CAUTION

:

  

Changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

C.

 

Software

 

License

 

Agreement

 

 

 

The

 

purchase

 

of

 

a

 

B

Alert

 

X10

 

sensor

 

headset

 

entitles

 

the

 

Purchaser

 

a

 

nonexclusive,

  

single

use

 

software

 

license

 

(“Software”)

 

from

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

subject

 

to

 

the

 

following

 

conditions:

 

 

The

 

Purchaser

 

may

 

install

 

the

 

Software

 

on

 

only

 

one

 

computer,

 

make

 

one

 

copy

 

in

 

machine

 

readable

 

form

 

solely

 

for

 

backup

 

purposes,

 

provided

 

that

 

you

 

reproduce

 

all

 

proprietary

 

notices

 

on

 

the

 

copy;

 

and

 

physically

 

transfer

 

the

 

Software

 

from

 

one

 

computer

 

to

 

another

 

provided

 

that

 

the

 

Software

 

is

 

used

 

only

 

on

 

one

 

computer

 

at

 

a

 

time.

   

The

 

Purchaser

 

may

 

not

 

copy,

 

distribute,

 

rent,

 

lease,

 

sub

license,

 

transfer

 

or

 

use

 

the

 

Software

 

except

 

as

 

allowed

 

herein.

  

The

 

Purchaser

 

may

 

not

 

alter,

 

modify,

 

decompile,

 

translate,

 

disassemble

 

the

 

Program;

 

or

 

use

 

it

 

to

 

create

 

a

 

derivative

 

work.

  

Purchaser’s

 

right

 

to

 

use

 

this

 

Software

 

automatically

 

terminates

 

upon

 

failure

 

to

 

comply

 

with

 

any

 

provision

 

of

 

this

 

License

 

or

 

upon

 

your

 

destruction

 

of

 

all

 

copies

 

of

 

the

 

Program

 

and

 

documentation.

  

Purchasers

 

in

 

good

 

standing

 

will

 

be

 

offered

 

future

 

improvements

 

or

 

upgrades

 

to

 

the

 

Software.

  

If

 

Purchaser

 

purchases

 

an

 

upgrade

 

version

 

of

 

the

 

software,

 

it

 

constitutes

 

a

 

single

 

product

 

with

 

the

 

Software

 

that

 

the

 

purchaser

 

upgraded.

This

 

License

 

is

 

deemed

 

made,

 

accepted

 

and

 

delivered

 

in

 

the

 

State

 

of

 

California

 

and

 

shall

 

be

 

construed,

 

interpreted

 

and

 

governing

 

by

 

the

 

laws

 

of

 

the

 

State

 

of

 

California,

 

without

 

regard

 

or

 

effect

 

given

 

to

 

its

 

or

 

any

 

other

 

jurisdiction’s

 

conflicts

 

of

 

law

 

jurisprudence.

 

D.

 

Product

 

Limited

 

Warranty

 

 

The

 

B

Alert

 

X10

 

Sensor

 

Headset

 

product

 

is

 

warranted

 

to

 

be

 

free

 

from

 

defects

 

in

 

material

 

and

 

workmanship

 

under

 

normal

 

use

 

and

 

service

 

for

 

a

 

period

 

of

 

180

 

days

 

from

 

the

 

date

 

of

 

delivery.

   

The

 

obligation

 

of

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

under

 

this

 

warranty

 

is

 

limited

 

to

 

repair,

 

re

work

 

or

 

replacement

 

at

 

Advanced

 

Brain

 

Monitoring,

 

Inc.’s

 

option,

 

of

 

any

 

Sensor

 

Headset

 

product

 

which,

 

within

 

the

 

180

 

days

 

from

 

date

 

of

 

delivery,

 

is

 

examined

 

and

 

determined

 

by

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

to

 

be

 

defective.

  

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

will

 

not

 

be

 

responsible

 

for,

 

and

 

the

 

warranty

 

shall

 

not

 

apply

 

to,

 

any

 

damage

 

caused

 

by

 

the

 

following:

  

natural

 

disasters,

 

war,

 

civil

 

disturbances,

 

abuse,

 

misuse,

 

negligence,

 

usage

 

of

 

incorrect

 

electrical

 

supply

 

voltage,

 

usage

 

not

 

in

 

accordance

 

with

 

the

 

operation

 

instructions

 

manual,

 

or

 

normal

 

wear

 

and

 

tear.

 

 

This

 

warranty

 

shall

 

not

 

apply

 

to

 

any

 

Sensor

 

Headset

 

product

 

which

 

has

 

been

 

repaired,

 

serviced,

 

disassembled

 

or

 

modified

 

by

 

any

 

party

 

other

 

than

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

  

No

 

warranty

 

claim

 

will

 

be

 

allowed

 

for

 

Sensor

 

Headset

 

products

 

damaged

 

by

 

improper

 

use,

 

operation

 

or

 

handling

 

after

 

delivery

 

of

 

the

 

Sensor

 

Headset

 

product.

   

Purchaser

 

must

 

file

 

all

 

claims

 

resulting

 

from

 

damage

 

in

 

transit

 

with

 

the

 

carrier

 

or

 

carrier’s

 

agent.

  

Expenses

 

incurred

 

in

 

connection

 

with

 

claims

 

for

 

which

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

is

 

not

 

liable

 

may

 

be

 

charged

 

to

 

the

 

Purchaser.

 

 

Upon

 

submission

 

of

 

a

 

warranty

 

claim,

 

Purchaser

 

is

 

deemed

 

to

 

have

 

waived

 

any

 

and

 

all

 

other

 

claims

 

against

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

Advanced

 

Brain

 

Monitoring,

 

Inc.

 

shall

 

in

 

BIOPAC Systems, Inc.

 

 

B-Alert X10 User Manual

 

|       

24

 

 

Summary of Contents for B-ALERT X10

Page 1: ...User Manual 42 Aero Camino Goleta CA 93117 805 685 0066 http www biopac com Distributed by BIOPAC Systems Inc Manufactured by Advanced Brain Monitoring Inc...

Page 2: ...n 9 C Application 11 D Additional ECG Placements 14 E Ready to Collect 14 F Post session Clean up 15 A Common Headset and Sensor Issues 17 Chapter 4 Specifications 19 A B Alert X10 19 B Environmental...

Page 3: ...ons The Sensor Headset collects physiological signals from the sensors placed on the user sampling at 256 Hz The headset performs analog to digital conversion encoding formatting and transmitting of a...

Page 4: ...ation are required B ALERT X10 has no alarms classifications such as drowsiness There are only alarms for indications of excessive artifact Do not use the B ALERT X10 as a substitute for clinical ECG...

Page 5: ...on the EEG sensors as this will cause permanent damage and void the Warranty This device has been tested and found to comply with the limits for medical devices to the IEC 60601 standards These standa...

Page 6: ...MB virtual memory Windows XP or Windows 7 operating system NET framework version 3 5 installed Minimum of 50 MB hard disk space per 5 hour session One CD ROM drive VGA or higher resolution video adap...

Page 7: ...oam Sensors 12cc Syringe ECG Leads left Mastoid right Disposable Electrodes Synapse Gel Bottle Tube Cleaning Tools Tweezers Electrode Brush ABM USB Host device B Alert Dongle left Optional ESU MC righ...

Page 8: ...inimum 8hrs It takes 2 3hrs to fully charge a headset To recharge the Headset follow the steps below 1 Verify the Headset is in the off position Insert the X10 cable adapter into the sensor headset 2...

Page 9: ...rough each side of the Sensor Headset strap holders and fasten the Velcro Do this equally to both sides but leave loose for easy application to subject later c Verify that the Mastoid Leads are plugge...

Page 10: ...the foam and dispense gel You should see the gel begin filling the center of the foam ii The gel can also be dispensed into the foam from the sides by pushing the tip into either side of the foam unti...

Page 11: ...a snug fit c d Verify that the Neoprene Strap is centered on the subject and that it is not resting on the ears e While holding the strip in front of the subject with the foam pieces facing away from...

Page 12: ...subject s head while maintaining the correct alignment on the scalp g h h i Verify that all sensor sites are contacting the head and adjust straps if necessary j j Gently plug connector on the back o...

Page 13: ...4 Mastoids and ECG Leads BIOPAC Systems Inc B Alert X10 User Manual 13...

Page 14: ...thing or muscles which can compromise signal integrity Contact BIOPAC for additional information on alternative ECG placement E Ready to Collect 1 Plug in the USB Host Device B Alert Dongle or ESU to...

Page 15: ...the number of obstructions and avoid metal objects in the line of sight of the head and host units F Post session Clean up 1 Removal of Sensor Headset and Electrodes BIOPAC Systems Inc B Alert X10 Use...

Page 16: ...timal recordings clean the strip immediately after use Do not reuse foam sensors Strips are recommended for 25 30 uses Do not aggressively scrub the Sensor pads when cleaning If Sensor pad is removed...

Page 17: ...ensor Issues The following topics describe critical troubleshooting methods to undertake when encountering problems during the setup session of a subject Hands should be away from Face Part thick hair...

Page 18: ...Systems Inc B Alert X10 User Manual 18 NOTE The recommendations are not necessarily listed in a logical sequence Use best judgment to determine which trouble shooting tips are most relevant to the pro...

Page 19: ...either EEG or EOG Resolution 16 bit Bandpass Characteristics 0 1 Hz and 65 Hz at 3dB attenuation obtained digitally with Sigma Delta A D converter Noise 3 2 mV peak to peak out to 100 Kohms resistance...

Page 20: ...ration Transportation Storage Temperature 5o C to 40o C 41o F to 104o F 20o C to 70o C 4o F to 140o F 20o C to 70o C 4o F to 140o F Altitude 390 m to 3012 m 1254 ft to 9 882 ft 390m to 3012 m 1254 ft...

Page 21: ...he dealer or an experienced radio TV technician for help This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful int...

Page 22: ...determined by an electromagnetic site survey a should be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol...

Page 23: ...nsmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequenc...

Page 24: ...out regard or effect given to its or any other jurisdiction s conflicts of law jurisprudence D Product Limited Warranty The B Alert X10 Sensor Headset product is warranted to be free from defects in m...

Page 25: ...r any damage resulting from service work performed by the customer or its representative All returns to Biopac Systems Inc must include a Return Merchandise Authorization RMA obtained by calling Custo...

Reviews: