OPERATING PROCEDURE
BioOx Reactor 85
of
10
15
1. Add water and BioOx® Natural Media to the BioOx-85 at the Air/Water Inlet. (See photographs below).
Fill to Maximum Water Line. Plug the water pump cord into your electric outlet (120 volts). Make sure
water is circulating by listening for the sound of water flowing or seeing the water flow through the
Water/Air Inlet cover. (The water level should drop slightly as water pumps up to the water box).
2. Plug the fan cord into the electric outlet (120 volts). Place hand near fan, making sure air is flowing out.
The BioOx-85 should now be operating automatically.
3. Maintain the water level above the water pump and between the Minimum and Maximum Water Level
Lines at all times.
4. Check water level daily. Add water periodically to maintain water level . Allowing the water level to get
too low will damage the pump.
5. Add BioOx® Natural Media regularly. We recommend adding 4 oz. every month, depending on your
particular air quality. During peak periods, add more BioOx Media or add more often (every week).
Add water at air/water inlet
Add BioOx Media at air/water inlet