9
5.1.1
Clearance
Distance
–
Parallel
Position
Parallel Position Clearance Distance
Position
Clearance
(mm)
(A) Rear
100
(B) Side
250
(C) Floor
protector
(front)
300
(D) Floor
protector
(side)
200
(E) Flue
(rear)
5.1.2.
Clearance
Distance
–
Corner
Position
Corner Position Clearance Distance
Position
Clearance
(mm)
(F) Side
120
(G) Side
120
(H) Floor
protector
(front)
300
(I) Floor
protector
(side)
200
(J) Flue
(rear)
*
Note that this temperature passed within the laboratories margin of uncertainty.
Technical Note:
!No flue shield is required!
1.
The clearance measurement A, B, F and J were taken from the distance between walls and
closest point of the appliance,
C and H was measured from the front of the fuel-loading
opening to the edge of the floor protector, D and I was measured from each side of fuel-
loading opening, E and J were calculated from the flue’s centre to the rear wall.
2. The flue was installed onto the flue spigot, extended centrally and vertically without bend
before and after penetration of the ceiling plane.
3. Drawings shown above are not to scale.
A
B
C
E
D
D
F
G
H
J
I
I