Bionic fire RAIS User Manual Download Page 18

 
 

18

 

 

8.4.5

 

Cleaning

 

the

 

combustion

 

chamber.

 

Scrape

 

or

 

shovel

 

the

 

ash

 

out

 

and

 

store

 

it

 

in

 

a

 

non

flammable

 

container

 

until

 

it

 

has

 

cooled

 

down.

 

You

 

can

 

dispose

 

the

 

ash

 

with

 

your

 

normal

 

household

 

waste.

 

REMEMBER!

 

Never

 

remove

 

all

 

the

 

ashes

 

from

 

the

 

combustion

 

chamber

 

 

the

 

wood

 

will

 

burn

 

at

 

its

 

best

 

with

 

a

 

layer

 

of

 

ashes

 

of

 

approx.

  

20

 

mm.

  

 

Remove

 

gently

 

the

 

steel

 

dome

 

and

 

the

 

small

 

front

 

glass

 

(ash

 

stop).

 

 

 

 

 

 

 

 

Regarding

 

the

 

cleaning

 

of

 

the

 

upper

 

combustion

 

chamber

 

the

 

ash

 

pan

 

can

 

be

 

used.

 

The

 

pan

 

is

 

placed

 

underneath

 

the

 

UCC

 

in

 

2

 

brackets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The

 

ash

 

pan

 

must

 

not

 

remain

 

under

 

the

 

upper

 

combustion

 

chamber:

 

 

The

 

door

 

cannot

 

be

 

closed

 

and

 

can

 

be

 

damaged.

 

Front

 

glass

 

(ash

 

stop)

 

Dome

 

Ash

 

pan

 

Bracket

 

The

 

ashes

 

are

 

swept

 

on

 

to

 

the

 

ash

 

pan

 

and

 

disposed

 

of.

 

Replace

 

the

 

ash

 

pan

 

in

 

its

 

position

 

in

 

the

 

lower

 

combustion

 

chamber

 

again.

 

Summary of Contents for RAIS

Page 1: ...i Ohakune Road RD 3 Raetihi Phone 06 485 4871 Mobile 021 24 24 211 Email rene haeberli envirosolve co nz Web www envirosolve co nz Authorisation number 152619 AS NZS 4012 4013 Authorisation number 154...

Page 2: ...1 1 Clearance Distance Parallel Position 9 5 1 2 Clearance Distance Corner Position 9 6 For the installer 10 6 1 Operating instructions 10 6 1 1 Fuel 10 6 1 2 Drying and storage 11 6 1 3 Room ventilat...

Page 3: ...around the door 21 9 2 Soot on glass 21 9 3 Stove is burning too strong 21 9 4 Stove is burning too weakly 21 10 Secure the fire 22 Appendix 23 1 Drawings for the spare part 23 2 Legend for the spare...

Page 4: ...ished Shut the door properly afterwards Use only dry wood i e wood with a humidity of 15 22 The oven is wrapped in packaging that is recyclable This must be disposed accordingly to national rule regar...

Page 5: ...commend that you note down the number in the table below The production number is located on the back of the stove at the bottom 2 1 Warranty Your Rais wood burning stove come with a 5 year warranty T...

Page 6: ...height mm without socket 472 482 1064 Combustion chamber s width depth height mm Upper combustion chamber 280 200 300 Recommended amount of when fuelling kg Distributed p 1 2 logs of wood approx 25 c...

Page 7: ...building and safety regulations Attention is drawn in particular to the following 4 1 1 Handling The appliance is a heavy item and adequate facilities must be available for loading unloading and site...

Page 8: ...here to set up your RAIS wood burning stove you should consider the heat distribution to the other rooms This will enable you to get the best use out of your stove The stove should be set up at a safe...

Page 9: ...laboratories margin of uncertainty Technical Note No flue shield is required 1 The clearance measurement A B F and J were taken from the distance between walls and closest point of the appliance C and...

Page 10: ...nce with AS NZS 4012 4013 and AS NZS 2918 2001 Appendix B for stocking dried firewood The firewood must have a water content of 15 22 and it maximum length should be the width of the combustion chambe...

Page 11: ...d it 6 1 3 Room ventilation and stoves If there is an extractor fan in the same room as the bionic fire please make sure that the bionic fire is not closer than 2 meter to the extractor fan The stove...

Page 12: ...y combustion zone i e the bed of glowing embers The cold air is only used in the lighting stage Secondary air is added in the gas combustion zone i e air which contributes to the combustion of the pyr...

Page 13: ...rge temperature differences witch the material is subjected to Never use any type of liquid fuel for kindling or maintaining the fire There is a danger of explosion The stove gets very hot when in use...

Page 14: ...or window close to the wood burning It here is a storm in the stove coming from the chimney it is advisable to place a screwed up piece of newspaper between the upper baffle plate and the chimney set...

Page 15: ...too low too small ember it may take longer for the flames to be diverted to the LCC and thus achieve a cleaner burns When firing the smoke out of the chimney should be almost invisible just a flicker...

Page 16: ...d possible injure personal If there are only a few embers remaining you must light the fire again If you just add firewood the fire will not be lit but unburned exhaust gases will develop Here firewoo...

Page 17: ...ean damp cloth If the opaque mark frosting doesn t come out contact you dealer for a special remover 8 4 2 Paint finish The appliance has been coated with a high temperature paint which can last for y...

Page 18: ...er of ashes of approx 20 mm Remove gently the steel dome and the small front glass ash stop Regarding the cleaning of the upper combustion chamber the ash pan can be used The pan is placed underneath...

Page 19: ...cess the flue ways gently remove the smoke converter plate vermiculite by tilting I t to one side and turning it a little slantwise Pull out the plate carefully Remove dirt and dust and the parts in r...

Page 20: ...ng the plates 2 The bottom plate is gently lifted out of its position with a wide slotted screwdriver 3 The side plate is gently removed 4 The back plate is gently removed 5 Remove dirt and dust and m...

Page 21: ...when firing up prior to closing the door 9 3 Stove is burning too strong It could be caused by Leak around the door seal Chimney draught is too large 22 Pa draught regulator should be installed 9 4 S...

Page 22: ...t Where required by the regulatory authority provision shall be made for seismic restraint of the floor protector and the appliance Sufficient restraint shall be provided to resist a seismic loading e...

Page 23: ...23 Remove the adjustable feed from the stove Use the M8 threads to bolt the fire to the floor Appendix 1 Drawings for the spare part...

Page 24: ...24 2 Legend for the spare parts...

Page 25: ...25 3 Technical drawing of the bionic fire...

Reviews: