background image

Commissioning

RS232 Triggering

Make a cable using the 3 pins : TX, RX and G (GND) Set the RS232 parameters to : 9600bds 8 bits, no Parity, 2 Stop bits

To play a scene, send 3 bytes : 1 x y 255
To stop a scene, send 3 bytes : 2 x y 255
To pause a scene, send 3 bytes : 3 x y 255
To release a pause, send 3 bytes : 4 x y 255
To reset a scene, send 3 bytes : 5 x y 255

When (y)=0, (x) can be set between 0 and 255 -to stop scene 145, send the command: 2 145 0 255 When (y)=1, (x) can be set between
0 and 243 to trigger scenes 256-499 -to play scene 300, send the command: 1 255 45 255

TCP Triggering

The controller can be connected to an existing automation system over a network and triggered via TCP package on port 2431 or UDP
packets on 2430. Refer to the remote protocol document for more information.

Network Control

The controller can be connected to a local network, allowing it to be controlled from a smartphone or tablet over WiFi.

Connect the controller to a router or switch with an RJ45 cable
The controller is set by default to get an IP address from the router via DHCP. If the network is not working with DHCP, a manual
IP address and subnet mask can be set using the Hardware Manager
If the network has a filewall enabled, allow ports 2430 and 2431

6 | www.biontechnologies.com

Summary of Contents for cambium xl

Page 1: ...cambium xl USER MANUAL BEDIENUNGSANLEITUNG www biontechnologies com...

Page 2: ...ature proof up to 90 C Do not operate the device with inductive consumers fluorescent lamps gas discharge lamps ventilators etc in the same electric circuit Activation of inductive consumers can cause...

Page 3: ...receipt In delivery included cambium xl device Power Supply CD with Software User Manual If you detect any transportation damage or differencies between specified packing contents and your unpacked d...

Page 4: ...o gang back box Housing Color s Glass White Frame Plastic black Weight 0 25 kg 0 55 lbs Ingress Protection IP20 Warranty 24 Months Certification Zusatzinformation Remote Control Apps for iOS Android D...

Page 5: ...Mounting www biontechnologies com 5...

Page 6: ...command 1 255 45 255 TCP Triggering The controller can be connected to an existing automation system over a network and triggered via TCP package on port 2431 or UDP packets on 2430 Refer to the remot...

Page 7: ...ESA Pro Software Windows Timeline Multi Zone http www nicolaudie com en esapro htm ESA2 Software Windows Mac Single Zone http www nicolaudie com esa2 htm Hardware Manager Windows Mac Firmware clock h...

Page 8: ...rating to white between 100 and 200 M Lock Control Once this is enabled you can hold the dimmer button for 5 seconds to enable disable lock mode It s automatically activated after 120 seconds When loc...

Page 9: ...he router if not set to DHCP MAC Address a unique ID used to identify the controller on the network Date Time D Manages the date and time stored inside the controller Date the controllers date Time th...

Page 10: ...solvent free cleaning agents only and do not employ aggressive chemicals or high pressure cleaner Operate device only after complete drying Conformity Manufacturer Bion Technologies GmbH Lindberghstra...

Page 11: ...Fax 49 0 8231 95787 29 www biontechnologies com info biontechnologies com YouTube http www youtube com user BIONTECHNOLOGIES 2016 BION TECHNOLOGIS GMBH All rights reserved Subject to change Specificat...