Dear Bioland Blood Glucose Monitoring System Owner: 

Thank

 

you

 

for

 

choosing

   

this

 

system!

 

This

 

manual

   

contains

 

important

   

information

   

you

 

must

 

know

 

about

 

the

 

system.

 

Please

 

read

 

it

 

thoroughly

 

and

 

carefully.

 

The

 

system

 

provides

 

No

 

Code

 

function

 

which

 

means

 

that

 

you

 

don't

 

need

 

to

 

calibrate

 

your

 

meter

 

making

 

it

 

easier

 

for

 

the

 

user

 

to

 

monitor

   

blood

 

glucose

 

at

 

home.

 

 

IMPORTANT SAFETY INSTRUCTIONS 

The

 

meter

 

and

 

lancing

 

device

 

are

     

for

 

single

 

patient

 

use.

 

Do

 

not

 

share

 

them

 

with

 

anyone

 

including

 

other

 

family

 

member!

 

Do

 

not

 

use

 

on

 

multiple

 

patients!

 

AlI

 

parts

 

of

 

the

 

kit

 

are

 

considered

 

biohazardous

 

and

 

can

 

potentially

 

transmit

 

infectious

 

diseases

 

even

 

after

 

you

 

have

 

performed

 

cleaning

 

and

 

disinfection.

 

 

Changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

party

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)

 

this

 

device

 

may

 

not

 

cause

 

harmful

 

interference,

 

and

 

(2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation.

 

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

 

This

 

equipment

 

generates,

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

   

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

‐‐ 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

‐‐ 

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

 

‐‐ 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

‐‐ 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

 

 

READ THIS BEFORE USING 

DANGER

  ‐ 

Misuse

 

of

 

this

 

electrical

   

device

 

can

 

cause

 

electrocution,

 

burns,

 

fire

 

and

 

other

 

HAZARDS.

 

Basic

 

safety

 

precautions

   

should

 

always

 

be

 

taken,

 

including

 

all

 

those

 

listed

 

below.

 

Close

 

supervision

   

is

 

necessary

   

when

 

equipment

   

is

 

used

 

by,

 

on,

 

or

 

near

 

children,

   

Summary of Contents for G-427B

Page 1: ...Bioland Blood Glucose Monitor Model G 427B OWNER S MANUAL ...

Page 2: ...ipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inte...

Page 3: ...al 4 Do not use adjunct which are not supplied by the producer 5 Do not make the device come into contact with surfaces which are too hot to touch 6 Do not use the device where aerosol sprays are being used 7 Do not use the device if it is not working properly or if it has been damaged 8 Read all the manual and practice the test and then use the product to test your blood glucose Do all quality co...

Page 4: ...G THE MEMORY 8 THE TWO MEASURING MODES 11 TESTING WITH BLOOD SAMPLE 11 Overview of the Lancing Device 12 Setting Up the Lancing Device 12 Preparing the puncture site 13 Performing a Blood Glucose Test 13 Comparing Meter and Laboratory Results 15 CONTROL SOLUTION TEST 15 VIEWING RESULTS ON THE METER 16 CARE AND STORAGE FOR YOUR SYSTEM 17 Cleaning and Disinfection 17 METER SPECIFICATION 18 Limitatio...

Page 5: ... intended for self testing outside the body in vitro diagnostic use by people with diabetes at home as an aid to monitor the effectiveness of diabetes control The Blood Glucose Monitoring System is not to be used for the diagnosis of or screening of diabetes or for neonatal use The Test Strips are for use with the Blood Glucose Meter to quantitatively measure glucose drawn from the fingertips Caut...

Page 6: ... lead to transmission of Human Immunodeficiency Virus HIV Hepatitis C Virus HCV Hepatitis B Virus HBV or other bloodborne pathogens AST in this system can be used only during steady state blood glucose conditions described in the section of About AST Test principle The test is based on the measurement of electrical current generated by the reaction of glucose with the reagent of the strip The mete...

Page 7: ... not be used in insulin doses calculations Do NOT use AST if You think your blood glucose is low You are unaware of hypoglycemia You are testing for hyperglycemia Your AST results do not match the way you feel Your routine glucose results are often fluctuating CONTENTS OF THE KITS A Meter Carry Case Owner s Manual Two AAA Alkaline Batteries Test Strips Optional Lancing Device Sterile Lancet Option...

Page 8: ...ppears when the meter is turned on 3 LOW BATTERY SYMBOL Appears when the battery power is low 4 MEASUREMENT UNIT Appears with the test result in mg Ml or mmol L 5 CTL SYMBOL Appears when doing a Control test and indicates That the result won t be Stored in the memory 6 MEMORY SYMBOL Appears when you review the memory 7 TEST RESULT AREA Displays glucose results 8 KETONE WARNING Appears when your re...

Page 9: ...G THE METER AND DELETING THE MEMORY 1 Setting the language and voice volume 1 1 Setting the language Press and Hold S button for 3 seconds until the ENG or ESP is flashing Press M button to select a language you desire Press S 1 2 Setting the Volume With the Volume level number flashing Press M button to select level between 0 7 set 0 to turned off voice Press S 2 Setting the date and time 2 1 Set...

Page 10: ...ete the memory press the S button to skip this step The meter will automatically turn OFF and the set up will be completed NOTE The date time unit and memory deletion can ONLY be set in the setting mode When the meter is in setting mode if no button is pressed within 3 minutes the meter will turn off No set up necessary meter is pre set Meter is pre set for Eastern Standard Time Please refer to pa...

Page 11: ...is applied onto the test strip Beep When the test is completed result appears on display Your blood glucose is number milligrams per deciliter When the test result is 20mg dL Your blood glucose is less than 20 milligrams per deciliter When the test result is 600mg dL Your blood glucose is over 600 milligrams per deciliter When selected CTL for control solution testing Control solution mode Recall ...

Page 12: ...ch mode by 1 Start with the meter turned off Insert a test strip to turn on the meter the screen will display a flashing blood drop 2 Press M to select General or CTL mode TESTING WITH BLOOD SAMPLE CAUTION To reduce the chances of infection Choose a clean dry work surface Never share a lancing device and lancet with another person Always use a new and sterile lancet Lancets are for single use only...

Page 13: ... are for single use only Avoid ge ng hand lo on oils dirt or debris when handling the lancets Setting Up the Lancing Device 1 Screw the lancing device cap off Insert a needle into the lancet holder and push down firmly until it is fully in place 2 Screw the needle cap and place it in appropriate location to use again after finish blood taking 3 Replace the lancing device cap Turn the cap until it ...

Page 14: ...fference was significantly reduced Please follow the suggestions below before obtaining a drop of blood Rub the puncture site for about 20 seconds before penetration Select the puncture site either at the fingertips or another body part please see section Alternative Site Testing AST on how to select the appropriate sites Clean the puncture site using cotton moistened with 70 alcohol and let it ai...

Page 15: ... soon as enough blood has filled the confirmation window of the test strip you will hear a beep letting you know the test has begun A countdown of 5 seconds starts Note make sure the confirmation window of the Test Strip is completely filled with your blood sample Step 7 Your blood glucose level along date and time appears on the display Blood glucose results are automatically stored in the memory...

Page 16: ... you obtain from your meter may differ somewhat from your laboratory result due to normal variation Meter results can be affected by factors and conditions that do not affect laboratory results in the same way To make an accurate comparison between meter and laboratory results follow the guidelines below Before going to the lab Do a control solu on test to make sure that the meter is working prope...

Page 17: ...t directly apply control solution onto a strip Step 4 The result of the control solutions test appears on the display The result will not be stored under CTL mode The result of the control solutions test should be within the range printed on the test strip vial label If the test results falls outside the specified range printed on test strip vial label repeat the test Results falling outside the s...

Page 18: ...he Blood Glucose Monitoring System Test strip and Control Solution to extreme conditions such as high humidity heat freezing cold or dust The storage conditions for the test strips are 39 86 Humidity 80 RH Storage conditions for the meter are 40 131 Humidity 80 RH Always wash your hands with soap and water and rinse and dry completely before handling the Blood Glucose Monitoring system and Test st...

Page 19: ... is being operated by a second person who is providing testing assistance to the user the meter and lancing device shall be cleaned and disinfected first 3 The users should wash hands thoroughly with soap and water after handling the meter lancing device or test strips METER SPECIFICATION Model G 427B with Bioland test strip and control solution Machine size 90mm L 54mm W 13mm H Weight 50g excludi...

Page 20: ...mg dL Bilirubin 15mg dL Dopamine 0 03mg dL L dopa 0 45mg dL Methyldopa 0 75mg dL Tolbutamide 24mg dL Triglycerides 2000mg dL Hemoglobin 250mg dL Pa ents undergoing oxygen therapy may yield falsely lower results Not for use for pa ents in a hyperglycemic hyperosmolar state with or without ketosis Not for use on critically ill patients Not to be used for pa ents who are dehydrated hypertensive hypot...

Page 21: ...be installed improperly 2 Battery power is too low for use 3 Too much time has passed between inserting the Test Strip and perfor ming the test 44 Test Strip has not been fully inserted into the Meter 1 Install the Battery correctly 2 Replace with new Battery 3 Reinsert the Test Strip into the Meter 4 Reinsert the Test Strip into the Meter Test results are incon sistent or Control Solution test re...

Page 22: ...eter co untdown did not start Test Strip has not been inserted correctly Use a new Test Strip and redo the test Bioland Technology LTD No A6B7 Block G ShangRong Industrial Zone No 5 Baolong Road Baolong Community Longgang District 518116 Shenzhen Guangdong PEOPLE S REPUBLIC OF CHINA Version V1 0 2016 01 by Bioland Technology LTD ...