background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for eLine 730020

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...eLINE Instruction Manual Bedienungsanleitung Mode d emploi Manual Usario Instruzioni d impiego san Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisan...

Page 3: ...Instruction Manual 1 Bedienungsanleitung 35 Mode d emploi 71 Manual Usario 105 Instruzioni d impiego 139 eLINE san Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisan...

Page 4: ...ipetting P MANUAL 15 8 MULTI MODES 16 8 1 Multi dispensing d 17 8 2 Diluting dd and diluting with mixing dd MIXING 18 8 3 Sequenced dispensing Sd 19 8 4 Multi aspirating SA 20 8 5 Automatic dispensing...

Page 5: ...protocols typically required by laboratories currently The simple keyboard and easy to read display together with user friendly operation and programming allows these tasks to be performed quickly an...

Page 6: ...m the type of order However all Biohit eLINE pipette packages contains Pipette Tip Safe Cone Filters and Filter Forceps 10 l Grease in single channel units only Instructions for use Performance certif...

Page 7: ...attery Cover Charging Contacts Reset Button Finger Hook Tip Cone e5000 Tip Ejector Assembly e5000 4 PIPETTE DESCRIPTION 4 1 Display and controls The control and programming of the Biohit eLINE pipette...

Page 8: ...piston Press to remove tip Press to reset the movements pipette Mode Ranges and Operating Mode Symbols PROG PROG 1 6 6 storage locations MULTI d multi dispensing dd diluting dd MIXING diluting with mi...

Page 9: ...piston will stop in the lowest position until the button is released In the operating modes with automatic blow out P dd the piston will automatically return to the home position after the start butto...

Page 10: ...after 50 250 pipetting cycles and always in case of over aspiration The Biohit Filter Forceps should be used to avoid touching the soiled filters by hand Fig 3 See Chapter 2 1 for ordering informatio...

Page 11: ...nd China plugs 1 Check that the battery protector is removed and the battery cover is properly closed 2 Place the pipette into the Charging unit Make sure that the metal contacts at the rear of the pi...

Page 12: ...the pipette 4 The charging time is 12 hours for a completely discharged battery Note It is possible to continue pipetting while the eLINE pipette is charged through the AC adaptor Fig 7 With fully dis...

Page 13: ...nter key In the shortcut programming the changes are confirmed with the Enter key In the shortcut programming the speed adjustment is not possible The use of the Select key in confirming the setting c...

Page 14: ...speed excluding speed Prog 1 6 was chosen Start pipetting Store the operating mode with Change selected settings with settings to Prog 1 6 Start pipetting P MANUAL is not available in multichannel mo...

Page 15: ...with automatic blow out rP Reverse pipetting without blow out P MIXING Pipetting with blow out followed with mixing function P COUNT Pipetting with blow out and displayed cycle counter P MANUAL Manua...

Page 16: ...p in to the solution then press and hold the START button Mixing is performed automatically as long as the START button is held down 2 Position the tip to dispense Press START button twice Note The mi...

Page 17: ...e START button to aspirate the next sample 7 3 Pipetting with cycle counter P COUNT The eLINE performs pipetting with blow out and the cycle counter function The cycle counter counts up to 99 pipettin...

Page 18: ...the manual pipetting mode the aspiration and dispensing are controlled manually The aspiration or dispensing continues as long as the START button is held down within the selected volume range The asp...

Page 19: ...aton dispensing direction 12 Position the tip to dispense Press the START button 13 When the tip is empty volume reaches 0 l within one second the display will show E Position the tip to empty the tip...

Page 20: ...and to display the speed out 10 Select the speed out with 1 Min and 9 Max 11 Press or to confirm selections 12 Position the tip to aspirate and press the START button The display shows PRE OUT and ar...

Page 21: ...play starts to scroll faster 5 Press or to confirm the selection 6 Select the desired sample volume volume 2 with 7 Press to confirm selection and to display the speed in or press and continue from St...

Page 22: ...e nominal volume of the pipette 1 Press to display MULTI 2 Scroll with until the symbol Sd is displayed 3 Confirm by pressing 4 Select the number of dispensing steps by using 5 Press or to confirm the...

Page 23: ...e the tip into the liquid again and then release the START button to aspirate the next sample 8 4 Multi aspirating SA The pipette performs consecutive aspiration operations of the programmed volume Th...

Page 24: ...desired dispensing volume by using the Note When holding down the volume display starts to scroll faster 5 Press or to confirm the selection and to display the aliquots 6 Select the desired number of...

Page 25: ...ion To continue press the START button immediately after E is displayed and within one second the direction arrow will change Keeping the START button depressed place the tip into the liquid again and...

Page 26: ...h Biohit eLINE pipettes The operating modes P P MIXING P COUNT dd dd MIXING and SA feature an automatic blow out and others leave an excess liquid in the tip The user should follow the recommendations...

Page 27: ...xcessive force when mounting the tips as this can hamper the tip ejection Avoid rough handling light pressure is all that is required when using the keyboard or mounting the tips Do not drop the pipet...

Page 28: ...panol 60 or mild detergent and soft lint free cloth The interior of the tip ejector collar and tip cone can be cleaned with a cotton swab Rinse with distilled water if needed Let the parts dry Grease...

Page 29: ...the movement Test the tip ejection operation Note When reassembling the pipette do not over tighten the parts Note It is always necessary to check the performance of the pipette after in house service...

Page 30: ...Stand or Carousel However during long storage periods several months it is recommended to disconnect the Charging Stand and Carousel from the mains outlet It is also advisable to remove the battery pa...

Page 31: ...with the correction factor Z Z values in the table below Vi mi Z 11 Calculate the mean volume v delivered v Vi 10 12 For conformity evaluation calculate the systematic error es of the measurement in...

Page 32: ...representative for further information The length of the piston stroke is electronically monitored and the pipette does not normally need recalibration However for special applications the Biohit eLI...

Page 33: ...ohit eLINE pipettes have a onboard monitoring program to control the performance of each pipetting action If any error message appears to the display it means that the pipette has been unable to perfo...

Page 34: ...nt of grease on a piston and o ring Grease accordingly Pipette out of established specifications Instrument damaged Return to your Biohit service representative for servicing Pipette blocked aspirated...

Page 35: ...ipping by the manufacturer The Biohit Quality Assurance Procedure guarantees that the Biohit eLINE electronic pipette you have purchased is ready for use Each Biohit eLINE electronic pipette is CE IVD...

Page 36: ...0 60 l 0 70 0 30 12 l 2 00 1 50 1 24 730360 8 ch 10 300 l 300 l 0 50 0 20 150 l 0 70 0 30 30 l 2 00 1 00 1 30 730390 8 ch 50 1200 l 1200 l 0 50 0 20 600 l 1 00 0 30 120 l 2 50 1 00 1 24 730420 12 ch 0...

Page 37: ...device must not be recycled as unsorted municipal waste Instead this device must be collected separately in accordance the local recycling regulations The solid bar used in conjuction with the crossed...

Page 38: ...oment de la publication et ont t compil es avec le plus grand soin Biohit n est pas responsable des ventuelles erreurs ou omissions et se r serve le droit d apporter des modifications sans pr avis Tou...