SC-122420JUD CONTROLLER ADDENDUM
This is an addendum to the user manual. By default the SC-122420JUD is set to charge LiFePO4
batteries. To charge other battery chemistries, do the following:
1)
Press the Menu (left red) button until “b00” shows on the display
2)
Hold down the Menu (left red button) for 5 seconds, until the “b00” setting starts to flash.
3)
Push the Select (right red button) until “b01, b02, b03” shows up corresponding the following
b00 = LiFePO4
b01 = Flooded Lead Acid
b02 = AGM (Absorbed Glass Mat)
b03 = Gel
b04 = LiFePO4
b00 is the same as b04 settings