STATUS CODES
INDICATOR STATE
DESCRIPTION
MEANING
CHARGE/
PANEL
No Icons
PANEL OFF, FUNCTION ICON OFF
No Solar Panel detected
Panel Icon On
Function Icon Off
PANEL ICON ON, FUNCTION ICON
NOT INDICATING
Solar charging stopped
Panel Icon On
Function Icon On
PANEL AND FUNCTION ICON ON,
BATTERY ICON IS SCROLLING
Solar Panels are
charging Battery
LOAD
Function Icon On
Light Bulb Icon On
BOTH INDICATORS ARE ON SOLID
Load is ON
Function Icon Flashing
Light Bulb Icon On
LOAD INDICATOR ON, FUNCTION
INDICATOR FLASHING
Load is OFF
BATTERY
Battery Icon Empty
NO BARS
Battery requires
charging
Battery Icon Scrolling
SCROLLING BARS
Battery is charging
Battery Icon Full
FULL BARS, NO SCROLLING
Battery is fully charged
FAULTS AND REMEDIES
Contact Us
:
Bioenno Power
:
3657 W. McFadden Ave.
Phone
:
+1 888 336-7864
Santa Ana, California 92704
ERROR CODE
PHENOMENON
REMEDY
E01
BATTERY LOW VOLTAGE
CHECK OPERATION MODE,
CONFIRM OPERATION MODE IS
SET DEFAULT TO “AUTO” OR SET
TO CORRECT VOLTAGE IF YOU
ALREADY HAVE A SPECIFIC
SYSTEM ASSEMBLED
E02
OVERLOAD, LOAD IS OFF
DECREASE LOAD
E03
SHORT CIRCUIT, LOAD IS OFF
REMOVE BATTERY AND LOAD,
CONFIRM THERE IS NO REVERSE-
POLARITY, RE-ATTACH IN
CORRECT CONFIGURATION
E04
OVERVOLTAGE ON BATTERY,
LOAD IS OFF
CHECK BATTERY, CONFIRM
BATTERY IS APPROPRIATELY
SIZED FOR APPLICATION
E05
OVERCURRENT ON SOLAR
PANEL, CONTROLLER HAS
STOPPED CHARGING
CHECK PANEL OUTPUT, LOWER
PANEL OUTPUT IF TOO HIGH
*
Note
: In the event of a short circuit, your Solar Charge Controller trip an auto-reset fuse – disconnect load immediately, let it
stand for 10-20 minutes, the internal fuse will automatically reset during this period. Before resuming operation, confirm your