biodex 058-720 Installation & Operation Manual Download Page 3

- 3 -

INTRODUCTION
The Ultra Pro Ultrasound Table is a dedicated table for
all general ultrasound procedures including OB/GYN.
Choose from an assortment of table options to cus-
tomize the table to suit your department needs. 

This extra-wide table features a 500-lb patient load
capacity, contoured tabletop to maximize patient scan-
ning, and a vast height range down to 23" to facilitate
wheelchair transfers. The Ultra Pro also accommodates
bariatric patients.

Ergonomically designed to suit both patient and sonograph-
er, the table’s height range allows seated or standing work
positions. Pivoting side rails allow comfortable shoulder,
arm and hand positions when scanning. There are no barri-
ers between sonographer and patient, allowing correct
scanning posture to prevent musculoskeletal injury. The
open frame design allows sonographers to get closer to the
patient for carotid imaging or long leg arterial scanning.
The motorized Fowler back is infinitely adjustable up to 80°
via the hand or optional foot controller. 

For the patient, comfort is assured through lengthy proce-
dures with an amply thick mattress and a multitude of com-
fort-driven design details. For example, the retractable stir-
rups pivot from side-to-side and can be used partially or
fully extended while the foot cushion drops down to 40° for
patients with circulatory issues and 80° for stirrup access.
Biodex tables are so accommodating, they actually reduce
the total amount of time required to get a quality image.

The Ultra Pro Ultrasound Table is equipped with a motor-
controlled hand controller to actuate table positions, 2"- and
3"-thick table padding covered in easy-to-clean
Naugahyde

®

, two patient restraining straps with Velcro

®

hook and loop fasteners, five-inch swivel casters and a
central locking system, accessible from either side of the
table, to secure table position.

Additional accessories are available, including foot con-
troller, retractable stirrups, vascular scanning arm board,
pivoting side rails, IV pole and paper dispenser.

TABLE PARTS AND ADJUSTMENTS
(Refer to Figure 1.)

Figure 1. The Biodex Ultra Pro Ultrasound Table parts and
adjustment include:

Standard Parts and Adjustments:
1. Fowler Back
2. Seat Cushion
3. Foot Cushion
4. Foot Cushion Release Lever
5. Patient Ankle Restraints
6. 5" Swivel Casters
7. Central Locking System Lever
8. Hand-Held Controller
9. Patient Restraining Straps

Optional Parts and Adjustments:
A. Paper Dispenser (058-610)
B. Pivoting Side Rails (058-631)
C. Retractable Stirrups (058-651)
D. Foot Controller (058-740)
E. Side Rail Pull Pin
F. Vascular Scanning Arm Board Receiving Tube
G. Vascular Scanning Arm Board, not shown (058-735)
H. IV Rod, not shown (058-656)

A

1

B

2

F

9

E

8

7

D

6

5

4

3

C

Summary of Contents for 058-720

Page 1: ...TABLE INSTALLATION OPERATION MANUAL 058 720 058 725 BIODEX Biodex Medical Systems Inc 20 Ramsay Road Shirley New Y ork 11967 4704 Tel 800 224 6339 In NY and Int l call 631 924 9000 Fax 631 924 9241 Em...

Page 2: ...operating or servicing system ATTENTION Se r f rer la notice d utilisation avant d utiliser l equipement CAUTION Disconnect power from source before removing panel or covers Reliable grounding achiev...

Page 3: ...tially or fully extended while the foot cushion drops down to 40 for patients with circulatory issues and 80 for stirrup access Biodex tables are so accommodating they actually reduce the total amount...

Page 4: ...le Toute g ne ou difficult de mouvement Abissement inopin de la table Rouletted ou coussins de stabilisation des pattes endommag s ou desserr s Tous signes de dommages la structure de support de la ta...

Page 5: ...ccessories are provided with the table These include a 7 16 wrench 9 16 wrench and a Phillips screwdriver Foot Controller 058 740 The foot controller uses three separate rocker style pedals to control...

Page 6: ...ition the arm board receiving tube beneath the Fowler back support bar on the desired side Ensure that the arm board receiving tube screw holes align with the screw holes on the Fowler back support Th...

Page 7: ...Tighten the nut until snug do not over tighten 5 Position the rubber friction plate behind the front face of the stirrup housing and then position the metal backing plate behind it The rubber frictio...

Page 8: ...cushion so the four pre drilled screw holes in the bracket align with the screw holes under the seat cush ion The side rail should face up with the short end of the rail closest to the foot end cushi...

Page 9: ...nsure the pre drilled screw holes align with the screw holes from step 2 4 Using a 7 16 wrench install the two 1 4 20 hex head screws removed in step 1 through the dispenser mount ing bracket and tigh...

Page 10: ...om of the cushion so the two pre drilled screw holes in the bracket align with the screw holes on the tabletop frame The I V Pole should face up and away from the head end of the table 3 Using a 7 16...

Page 11: ...down or folds up for maximum access to the patient Mattress Torso section 2 5 cm thick center and leg sections 3 8 cm thick foam rubber pad covered with durable Naugahyde Upholstery Color Graphite Mot...

Page 12: ...Voltage Fluctuations Immunity EN 61000 6 1 EN 61000 6 2 EN 60601 1 2 EN 1970 Immunity to electrostatic discharges Immunity to electromagnetic fields Immunity to fast electric transients Immunity to s...

Page 13: ...13 OPTIONAL FOOT CONTROLLER...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ...22...

Page 23: ...BIODEX Biodex Medical Systems Inc 20 Ramsay Road Shirley New Y ork 11967 4704 Tel 800 224 6339 In NY and Int l call 631 924 9000 Fax 631 924 9241 Email sales biodex com www biodex com...

Reviews: