background image

                                                                          http://www.BioAxxis.com 

BioAxxis® BD1 

38 

 

 

 
 
 

 

 

 

A single short beep will be heard and 
the fingerprint sensor will power on 

 

Rest an Administrator’s 
fingerprint

 on the scanning window  

 

When the Administrator’s fingerprint 
is successfully 

verified

, a single, long 

beep will be heard indicating that the 
most recently enrolled fingerprint 
user has been deleted  

o

 

If you hear four beeps, this 
indicates that the verification 
of the Administrator’s 
fingerprint was not successful.  
Begin again from the first step 
of Section III 

 

Close the sliding cover 

 

Repeat steps from the beginning of 
Section III to delete the 

next 

most 

recently enrolled fingerprint user. 

 

Summary of Contents for BD-1

Page 1: ...he documentation carefully before installation use The manual details all installation procedures and operation steps Manufacturer and or Distributors of the BioAxxis BD1 will not be responsible for a...

Page 2: ...right length 12 4 4 Installation of the Outdoor Unit 14 4 5 Installation of the Indoor Unit 16 5 Trouble Shooting 23 Operation Manual 25 Section I Enrolling Administrators First 2 Fingerprint Users 28...

Page 3: ...rts in the packaging box of the BioAxxis BD1 If any part is missing or damaged contact our service center or your local dealer Outdoor Unit Indoor Unit Strike Lining Box Outdoor Rubber Gasket Strike P...

Page 4: ...ews Alkaline Batteries 2 Required Tools Electric or battery operated Drill One 3 8 Diameter Drill Bit One 1 Diameter Drill bit One 2 1 8 Diameter Drill Bit A Carpenter Chisel A Hammer A pair of scisso...

Page 5: ...bore holes on the door 3 11 Mark holes on door For doors with existing deadbolt lock with 2 1 8 diameter hole 1 Remove existing cylindrical deadbolt 2 Please be sure to use the installation template...

Page 6: ...your existing backset 2 3 8 or 2 4 Rest the installation template on the front of the door on top of the existing 2 1 8 hole making sure that it is aligned properly for the door s existing 2 3 8 or 2...

Page 7: ...http www BioAxxis com BioAxxis BD1 7 6 Bore the two 3 8 holes into the door using a 3 8 drill bit making sure that the holes fully penetrate through the door 7 Go to Section 4 3 in the User Manual...

Page 8: ...dge of the door bevel Mark the center point of the cylinder hole on the door face and then mark the center point of the deadbolt hole on door edge as indicated on the template B For installation of co...

Page 9: ...e door to avoid splintering B Bore a 1 diameter hole in the center of door edge for deadbolt C Bore two separate 3 8 diameter holes for the upper fixing posts 3 2 Deadbolt Latch Selection There are tw...

Page 10: ...the door follow the UP sign keeping it parallel to the face of the door Mark the outline of the face plate and remove the deadbolt B Then chisel 1 8 deep rectangular shape per your marking or until th...

Page 11: ...or jamb and then mark the vertical center lines 3 Extend the vertical center line and the horizontal line to mark the drill center point for the strike B Bore a 1 diameter and 1 deep hole in the door...

Page 12: ...t match exactly EX If your door is 1 thick then you must use the 1 long tailpiece The BioAxxis BD1 comes with the 1 tailpiece pre installed If your door is not 1 thick but the thickness matches one of...

Page 13: ...S If you need to trim the tailpiece be sure to measure the exact thickness of your door mark the tailpiece with a marker where it needs to be cut and trim the tail piece accordingly per the exact thic...

Page 14: ...http www BioAxxis com BioAxxis BD1 14 4 4 Installation of the Outdoor Unit 1 Attach the rubber gasket to the back of the outdoor unit 2 Make sure the tail piece is vertical...

Page 15: ...dbolt is engaged 4 Insert tail piece through the cross slot of the latch 5 Insert the connector and wire through the cylinder hole below the deadbolt latch 6 Insert the two upper fixing posts through...

Page 16: ...plate of the Indoor Unit If the door is left handed please push the orientation selector switch to L position if it s right handed switch the selector to R position Right Handed Left Handed 2 Left han...

Page 17: ...http www BioAxxis com BioAxxis BD1 17 3 Plug wire set into circuit board making sure all prongs are firmly seated 4 Press sheathing of wire casing into the wire holder clamp...

Page 18: ...http www BioAxxis com BioAxxis BD1 18 5 Turn the manual turn knob to the vertical position facing downward...

Page 19: ...o the vertical retaining slot of the indoor unit 7 Gently finish joining the outdoor and indoor units together ensuring all fixing posts are aligned properly 8 Fasten the two shorter screws through th...

Page 20: ...ioAxxis com BioAxxis BD1 20 9 Fasten the two long screws through the bottom fixing post holes on the inside unit 10 Move the manual turn knob back and forth to ensure that deadbolt opens and closes me...

Page 21: ...http www BioAxxis com BioAxxis BD1 21 11 Insert 4 high quality AA batteries...

Page 22: ...ed position It should turn freely If and when the inside and outside locks are attached securely and the inside knob doesn t turn freely see the trouble shooting table below for possible solution If t...

Page 23: ...e door thickness and swap or trim the tail piece per section 4 3 of the installation manual Indoor turn knob turns but nothing happens 1 The tail piece did not go through the cross slot of the deadbol...

Page 24: ...is in vertical position When the sliding cover is fully lifted and immediately put down to engage the deadbolt but the deadbolt does not fully engage or four alert beeps are heard 1 Improper position...

Page 25: ...ened and immediately closed Definitions of Indication Beeps Single Short Beep Indicates that any operations sequence has begun OR that the door has been successfully locked or unlocked OR that the sli...

Page 26: ...r Fingerprint Enrollment and Verification Generally the center of the vortex swirl of the fingerprint pattern is the key data point ideally it is placed in the center of the small glass window in a co...

Page 27: ...erprint 2 or 3 times at slightly different angles EX Enroll same pointer finger as users 3 4 and 5 Always wait until the fingerprint scanner turns on to place your finger on the scanning window This i...

Page 28: ...ATORS can apply all programming functions as well as verify their fingerprints to unlock the door The 3rd thru 30th fingerprint users enrolled Users 3 thru 30 are automatically programmed at the USER...

Page 29: ...e first fingerprint user ADMINISTRATOR1 USER 1 Remove the battery cover from the indoor unit Press the ADD button located on the indoor unit Single beep will be heard Fully open the sliding cover loca...

Page 30: ...first of three scans Keep your pointer finger on the scanning window thru all three scans After the scanning is completed you will hear one of the following o Single long beep indicating that the ope...

Page 31: ...e second fingerprint user ADMINISTRATOR2 USER 2 Remove the battery cover from the indoor unit Press the ADD button located on the indoor unit Single beep will be heard Fully open the sliding cover loc...

Page 32: ...d Immediately remove the ADMINSTRATOR S finger A single short beep will be heard and the fingerprint sensor will power on Rest the new 2nd ADMINISTRATOR S pointer finger on the sensor window during th...

Page 33: ...begin As noted in the Helpful Hints section the third thru thirtieth fingerprint users enrolled Users 3 thru 30 are automatically programmed at the USER level USER level fingerprints can only be used...

Page 34: ...4 Remove the battery cover from the indoor unit Press the ADD button located on the indoor unit Single beep will be heard Fully open the sliding cover located on the outdoor unit immediately Sensor wi...

Page 35: ...t the operation was successful OR o Four beeps indicating that your fingerprint was not successfully enrolled If you hear four beeps please start the enrollment process over from the beginning A singl...

Page 36: ...n The Individual Fingerprint User Deletion programming function deletes fingerprint users from the most recent fingerprint user enrolled to the earliest fingerprint user enrolled Please use the follow...

Page 37: ...BD1 37 With the battery cover removed press the DEL button located on the indoor unit Short Double Beep will be heard Fully open the sliding cover located on the outdoor unit immediately Sensor will f...

Page 38: ...sfully verified a single long beep will be heard indicating that the most recently enrolled fingerprint user has been deleted o If you hear four beeps this indicates that the verification of the Admin...

Page 39: ...ints will be deleted With no fingerprints enrolled in the BioAxxis BD1 the deadbolt will engage disengage when the sliding cover is fully opened and immediately closed Please use the following steps t...

Page 40: ...gerprint is successfully verified two long beeps will be heard indicating that ALL enrolled fingerprint users have been deleted o If you hear four beeps this indicates that the verification of the Adm...

Page 41: ...e BioAxxis BD1 from outside In case of emergency override keys can be used to disengage the deadbolt Please use the following steps to unlock the BioAxxis BD1 from outside with your enrolled fingerpri...

Page 42: ...s successful the deadbolt will disengage and a single short beep will be heard If verification of enrolled fingerprint was not successful then 4 short beeps will be heard If this happens the fingerpri...

Page 43: ...In case of emergency override keys can be used to engage the deadbolt Please use the following steps to lock the BioAxxis BD1 from outside when leaving Make sure your door is closed Open and immediat...

Page 44: ...ge the deadbolt Please use the following steps to lock and unlock the BioAxxis BD1 from inside Support Contact the BioAxxis BD1 dealer that you purchased the lock from OR Contact us at info bioaxxis c...

Page 45: ...http www BioAxxis com BioAxxis BD1 45 USER ENROLLMENT TABLE Number Hand R or L Finger Used Name...

Page 46: ...http www BioAxxis com BioAxxis BD1 46...

Reviews: