5.2
Selection of electrode diameter
There are 3 different electrode clamps (1.6, 2.4, 3.2 mm) supplied with the
machine.
Unscrew the electrode clamp from the electrode holder and replace with the
required size.
5.3
Selection of angle
!
Loosen slightly the knurled wheel (22).
!
Place the degree sign of the guide (20) at the selected angle.
!
Tighten the knurled screw (22).
Note:
15° is the smallest included angle of the electrode, that can be
ground.
180° position makes a flat on the electrode point.
(1 step = 5°)
6.
Using the Neutrix
!
Connect the machine to the power supply.
!
Adjust the machine speed according to the recommendations on page 8.
!
Select the electrode clamp to suit the tungsten to be ground.
6.1
How to operate Neutrix
!
Place the tungsten electrode in the electrode holder (5) with
approximately 35 mm protruding.
!
Push the electrode clamp into the depth setting gauge (12) until the clamp
is located into the allen screw (15), turn clockwise to tighten.
!
Put the electrode holder through the electrode holder guide (6) until the
tungsten is touching the diamond wheel, this operation can be observed
through the inspection cover (29).
!
Start the motor (11).