7.

 

Maintenance

Remove the plug from the power supply before carrying out any
maintenance or repairs.

7.1

 

Replacing the filter

The filter has to be changed when the amount of dust makes it difficult to
watch the grinding process through the inspection cover (29).

1.

 

Loosen the allen screw (25.3) at the filter housing (25).

2.

 

Remove the filter cover (25.2).

3.

 

Remove the filter cassette (26) and put it into the plastic bag for
disposal.

4.

 

Insert a new filter cassette so that the rubber seal is sitting tight to the
grinding head (2).

5.

 

Mount the filter cover and tighten the screw.

7.2

 

Replacing the diamond wheel

1.

 

Remove the electrode holder (5).

2.

 

Loosen the knurled screw (22)

3.

 

Unscrew the electrode holder guide (14) using the spanner (SW 17)

4.

 

Remove the grinding chamber (10) including the inspection cover
(29).

5.

 

Unscrew the nut retaining the diamond wheel, using the spanners
(SW14 & SW13), two flats are located on the motor spindle behind
the diamond wheel for this purpose.

6.

 

Remove the diamond wheel.

7.

 

Insert a new diamond wheel and replace the retaining nut.

8.

 

Replace the grinding chamber and inspection cover
Replace the electrode holder guide

9.

If the grinding head chamber is too dirty it can be cleaned with an
alkalised solution and rinsed with water.  

If doing so remember to

remove the filter first

Summary of Contents for Neutrix

Page 1: ...Page 1 NEUTRIX INSTRUCTION MANUAL...

Page 2: ...iameter 5 3 Selection of grinding angle 6 Using the Neutrix 6 1 Operating the Neutrix 6 2 How to grind the electrode 7 Maintenance 7 1 Replacing the filter 7 2 Replacing the diamond wheel 8 Parts diag...

Page 3: ...chine is undamaged Do not use the machine without the filter Change the filter in accordance with the instruction manual Only turn the machine on when the electrode holder is in the grinding chamber D...

Page 4: ...elect grinding position Grinding head Depth setting gauge Allen screw to tighten the grinding head On Off switch Mains cable 25 26 25 2 25 3 1 Filter housing Angle degree scale 1 step 5 Filter cassett...

Page 5: ...Inspection cover Allen screw 14 3 5 Grinding stop Diamond wheel Spindle for diamond wheel Electrode clamp 5 Electrode holder Stop Part Nos for electrode clamps 16 1 for 1 0 mm 16 2 for 1 6 mm 16 3 for...

Page 6: ...ng dust To be able to grind tungsten electrodes on site To achieve an exact and longitudinal ground tip 4 Technical data contents of standard package Motor 850 Watt Power 230V 50 Hz Insulation accordi...

Page 7: ...elect 3 different grinding positions Unscrew the knurled wheel 22 Lift the eccentric plate 20 and turn through 90 to the next position place the eccentric plate back in the slide of the angle adjustme...

Page 8: ...the electrode point 1 step 5 6 Using the Neutrix Connect the machine to the power supply Adjust the machine speed according to the recommendations on page 8 Select the electrode clamp to suit the tun...

Page 9: ...remove the electrode holder when the motor has come to a complete stop Place the electrode holder in the depth setting gauge Turn anti clockwise and the electrode can be removed Recommended turning sp...

Page 10: ...over and tighten the screw 7 2 Replacing the diamond wheel 1 Remove the electrode holder 5 2 Loosen the knurled screw 22 3 Unscrew the electrode holder guide 14 using the spanner SW 17 4 Remove the gr...

Page 11: ...Page 11 8 Parts diagram...

Page 12: ...4510200 22 Screw 1 piece N 44510220 25 Filter housing 1 piece N 44510250 25 2 Filter cover 1 piece N 44510252 25 3 Allen key to fix the filter cover M 5 x 6 1 piece N 44510253 26 Filter cassette 1 pie...

Reviews: