background image

Page  3 of 12

81883X

GENERAL DESCRIPTION

The Bink's Diaphragm Pump offers high volume delivery even at low air

pressure. Bink's pumps feature stall resistant design, modular air motor /

fluid sections.

Air operated double diaphragm pumps utilize a pressure differential in

the air chambers to alternately create suction and positive fluid pressure in

the fluid chambers, ball checks insure a positive flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to

pump and keep up with the demand. It will build and maintain line presĆ

sure and will stop cycling once maximum line pressure is reached (disĆ

pensing device closed) and will resume pumping as needed.

Models 818831 and 818836: The Acetal material used in these pumps

contains Stainless Steel fibers. It's conductivity allows it to be connected

to a suitable ground. A ground screw and ground wire kit is provided for

this.

AIR AND LUBE REQUIREMENTS

S

Use a filter capable of filtering out particles larger than 50 microns on

the air supply. There is no lubrication required other than the O" ring

lubricant which is applied during assembly or repair.

S

If lubricated air is present, make sure that it is compatible with the

Nitrile O" rings in the air motor section of the pump.

OPERATING INSTRUCTIONS

S

Always flush the pump with a solvent compatible with the material

being pumped if the material being pumped is subject to setting up"

when not in use for a period of time.

S

Disconnect the air supply from the pump if it is to be inactive for a few

hours.

S

The outlet material volume is governed not only by the air supply but

also by the material supply available at the inlet. The material supply

tubing should not be too small or restrictive. Be sure not to use hose

which might collapse.

S

When the diaphragm pump is used in a forcedĆfeed (flooded inlet)

situation, it is recommended that a Check Valve" be installed at the

air inlet.

S

Secure the diaphragm pump legs to a suitable surface to insure

against damage by vibration.

MAINTENANCE

S

Provide a clean work surface to protect sensitive internal moving

parts from contamination from dirt and foreign matter during service

disassembly and reassembly.

S

Keep good records of service activity and include pump in prevenĆ

tive maintenance program.

S

Service  Kits  are  available  to  service  three  separate  Diaphragm

Pump functions: 1. AIR SECTION, 2. DIAPHRAGM SECTION, 3.

BALL and SEAT SECTION.

 Santoprene 

R

 is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. 

S

 KeyĆLube

R

 is a registered trademark of Key Industries

Summary of Contents for 818830

Page 1: ...imum Particle Size 3 32 dia 2 4 mm Maximum Temperature Limits based on the materials of the following items Fluid Caps Manifolds Seats Diaphragms Seals Balls E P R 60_ to 280_ F 51_ to 138_ C Groundab...

Page 2: ...o not service or clean pump hoses or dispensing valve while the system is pressurized S Disconnect air supply line and relieve pressure from the sys tem by opening dispensing valve or device and or ca...

Page 3: ...tible with the Nitrile O rings in the air motor section of the pump OPERATING INSTRUCTIONS S Always flush the pump with a solvent compatible with the material being pumped if the material being pumped...

Page 4: ...035 SS L 2 O Ring 3 32 x 5 8 o d 1 B 3 O Ring 1 16 x 9 16 o d models 818834 818838 2 T 5 Diaphragm Washer 2 o d 2 873403 GFN 6 Diaphragm Washer 2 o d 2 873287 SS L 7 Diaphragm 2 T L 8 Diaphragm models...

Page 5: ...05 in lbs 10 7 11 9 Nm 26 Bolts 50 60 in lbs 5 6 6 8 Nm 62 Fluid cap nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in Apply pipe sealant to threads Apply Key Lub...

Page 6: ...o Mtl Part No Mtl Part No Mtl Part No Mtl Part No Mtl 1 Connecting Rod 1 873035 SS 873035 SS 873035 SS 873035 SS 873035 SS s L 2 O Ring 3 32 x 5 8 o d 1 B B B B B 3 O Ring 1 16 x 9 16 o d 2 T 5 Diaphr...

Page 7: ...ragm nut 95 105 in lbs 10 7 11 9 Nm 29 62 Fluid caps Manifold nuts 50 60 in lbs 5 6 6 8 Nm alternately and evenly then re torque after initial run in 63 Plugs 25 in lbs 2 8 Nm maximum Apply Keylube to...

Page 8: ...Carbon Steel SS Stainless Steel CK Ceramic SY Syn Seal DIAPHRAGM PUMP SERVICE GENERAL SERVICE NOTES S Inspect and replace old parts with new parts as necessary Look for deep scratches on metallic sur...

Page 9: ...rs and 142 washers on 118 pilot rod 2 Insert the stack into the 101 body Sleeve 103 may be used to as sist pressing stack into body 3 Install 103 sleeve and 102 O rings into 101 body 4 Install 143 pla...

Page 10: ...utlet hose S For the pump to prime itself it must be mounted in the vertical posi tion so that the balls will check by gravity S Check for pump cavitation suction pipe should be 1 2 minimum or larger...

Page 11: ...mm Dimensions shown are for reference only they are shown in inches and millimeters mm 10 1 16 256 mm 5 16 Slot 8 mm 7 1 2 191 mm 2 51 mm 6 1 8 156 mm Material Outlet 1 2 14 N P T F 1 Air Inlet 1 4 18...

Page 12: ...PN 876012 81883X Page 12 of 12...