TROUBLESHOOTING SPRAY PERFORMANCE
Always engage trigger lock and relieve fluid pressure.
!
CAUTION
PROBLEM
CAUSE
CORRECTION
Split spray pattern.
Not enough material flow.
Increase fluid flow by changing fluid tip size, or increase fluid
pressure.
Excessive bounce-back.
Too much atomization air pressure.
Reduce air pressure.
Gun too far from surface.
Check distance.
Runs and sags.
Too much fluid flow.
Adjust gun or reduce fluid pressure.
Material too thin.
Mix properly or apply light coats/reduce fluid flow.
Gun tilted at an angle.
Mount gun at right angle to work.
Thin, sandy coarse finish
drying before it flows out.
Gun too far from surface.
Check distance.
Too much air pressure.
Reduce air pressure and check spray pattern.
Fluid flow too low.
Increase fluid flow by changing fluid tip size, supply pressure.
EN
77-3131-R1.0 (12/2017)
7 / 16
www.carlisleft.com