Fluid inlet connection:
Fluid outlet connection:
'A'
'B'
400V 140 Nm 0.37 kW @ 50HZ
3.0 kW 4Pole 1400 RPM
460V 3PH 0.5 Hp @ 60HZ
SHC 630
Synthetic Oil
Gearbox Oil (EU Model)
Synthetic 220 (typically Agip Blasia S)
Gearbox Oil (USA Model)
Zone 1 II2G de IIC T4
Nominal pump stroke:
50mm [1.97 ins]
AC Induction Electric Motor- EU Model
Rated 20 to 80 Hz (c/w thermisters)
Rated 20 to 80 Hz (c/w thermisters)
Total Weight of Pump (inc electric motor)
1.66 l/m [0.44 US gal/m]
Fluid Output @ 80 HZ [40 cycles/min]
AC Induction Electric Motor - USA Model
6.64 l/m [1.75 US gal/m]
Reduce Maximum working pressure by 2 bar [29 psi] when using in Open Loop Flow Mode
Fluid Output @ 20 HZ [10 cycles/min]
1"
Sanitary
Nominal flow volume / cycle:
0.166 l/m [0.044 US gal/m]
EN
SPECIFICATION
Gearbox Ratio:
54:1
2 bar [29 psi]
Max. Inlet Pressure
e.g. E2-7 Maximum Set Pressure of 18 bar to operate Pump on a 24/7 basis
NOTE
Pressure when used in 'Smart Mode' (Closed Loop Pressure Mode)
20 bar [290 psi]
86 kg [176 lbs]
Class 1, Group D.
Maximum fluid pressure:
E2-7*
E2-7*
77-3245 R1.0
4/36