background image

 

BF (E1) 05/2016 

page 4/58 

 

Dear customer, 

For the correct operation of the chambers, it is important that you read this operating manual completely 

and carefully and observe all instructions as indicated. Failure to read, understand and follow the 

instructions may result in personal injury. It can also lead to damage to the chamber  and/or poor 

equipment performance. 
 

1. 

Safety 

This operating manual is part of the components of delivery. Always keep it handy for reference.  The 

device should only be operated by laboratory personnel especially trained for this purpose and familiar 

with all precautionary measures required for working in a laboratory. Observe the national regulations on 

minimum age of laboratory personnel. To avoid injuries and damage observe the safety instructions of the 

operating manual. 

 

 

WARNING 

Failure to observe the safety instructions. 
Serious injuries and chamber damage. 

  Observe the safety instructions in this operating manual 

  Carefully read the complete operating instructions of the chambers. 

 

1.1  Legal considerations 

This operating manual is for informational purposes only. It contains information for installing, start-up, 

operation and maintenance of the product. Note: the contents and the product described are subject to 

change without notice. 
Understanding and observing the instructions in this operating manual are prerequisites for hazard-free 

use and safety during operation and maintenance. In no event shall BINDER be held liable for any 

damages, direct or incidental arising out of or related to the use of this manual. 
This operating manual cannot cover all conceivable applications. If you would like additional information, 

or if special problems arise that are not sufficiently addressed in this manual, please ask your dealer or 

contact us directly by phone at the number located on page one of this manual 
Furthermore, we emphasize that the contents of this operating manual are not part of an earlier or existing 

agreement, description, or legal relationship, nor do they modify such a relationship. All obligations on the 

part of BINDER derive from the respective purchase contract, which also contains the entire and 

exclusively valid statement of warranty administration. The statements in this manual neither augment nor 

restrict the contractual warranty provisions.  
 

1.2  Structure of the safety instructions 

In this operating manual, the following safety definitions and symbols indicate dangerous situations 

following the harmonization of ISO 3864-2 and ANSI Z535.6. 

1.2.1  Signal word panel 

Depending on the probability of serious consequences, potential dangers are identified with a signal word, 

the corresponding safety color, and if appropriate, the safety alert symbol. 

 

DANGER

 

Indicates an imminently hazardous situation that, if not avoided, will result in death or serious (irreversible) 

injury. 

Summary of Contents for BF 115

Page 1: ...BF 400 BF400 230V 9010 0241 9110 0241 BF 400 UL BF400UL 120V 9010 0242 9110 0242 BF 720 BF720 230V 9010 0243 9110 0243 BF 720 UL BF720UL 120V 9010 0244 9110 0244 BINDER GmbH Address Post office box 1...

Page 2: ...7 6 CONTROLLER SETTING 17 6 1 Display entry of temperature and ventilation set points without ramp function 17 6 2 Display entry of temperature and ventilation set points with selected temperature ram...

Page 3: ...U 38 11 TROUBLESHOOTING 39 12 TECHNICAL DESCRIPTION 40 12 1 Factory calibration and adjustment 40 12 2 Definition of usable volume 40 12 3 Over current protection 40 12 4 Technical data 41 12 5 Equipm...

Page 4: ...n this operating manual are prerequisites for hazard free use and safety during operation and maintenance In no event shall BINDER be held liable for any damages direct or incidental arising out of or...

Page 5: ...n its proximity 1 2 2 Safety alert symbol Use of the safety alert symbol indicates a risk of injury Observe all measures that are marked with the safety alert symbol in order to avoid death or injury...

Page 6: ...in the same way in order to avoid disruptions that could result in direct or indirect injury or property damage 1 3 Localization position of safety labels on the chamber The following labels are loca...

Page 7: ...nal Special application acc to project no 0 40 kW Nominal power 1 8 A Nominal current 230 V 50 Hz Nominal voltage 10 at the indicated power frequency 230 V 60 Hz 1 N Current type With option internal...

Page 8: ...chambers With regard to operating the chambers and to the installation location please observe the DGUV guidelines 213 850 on safe working in laboratories formerly BGI GUV I 850 0 BGR GUV R 120 or ZH...

Page 9: ...and its behavior with the addition of heat energy Familiarize yourself with any potential health risks caused by the charging material the contained moisture constituent or by reaction products that...

Page 10: ...rving the instructions in this operating manual and conducting regular maintenance work chap 9 is part of the intended use WARNING If customer should use a BINDER chamber running in non supervised con...

Page 11: ...ent AISI 304 The housing is RAL 7035 powder coated All corners and edges are also completely coated All chamber functions are easy and comfortable to use thanks to their clear arrangement Major featur...

Page 12: ...sport the chamber using the door handle or the door Do NOT lift chambers size 400 and 720 by hand Lift chambers size 53 and 115 from the pallet at its four lower corners with the aid of 2 people chamb...

Page 13: ...four lower corners Place chambers size 400 and 720 using technical devices fork lifter on the transport pallet Set the fork lifter only from the rear in the middle of the chamber Make sure to place a...

Page 14: ...y 70 r H max non condensing Installation height max 3000 m 9842 ft above sea level When placing several chambers of the same size side by side maintain a minimum distance of 160 mm between each chambe...

Page 15: ...ied data located on the chamber s type plate chamber front behind the door bottom left hand chap 1 4 When connecting please observe the regulations specified by the local electricity supply company an...

Page 16: ...ly we recommend heating up the chamber to its nominal temperature for one day and in a well ventilated location 1 Insert the plug into an appropriate socket chap 4 1 The green Standby LED illuminates...

Page 17: ...splay The actual temperature value example 21 8 C is displayed 1 Press button The display shows alternately SP and the previous temperature set point example 60 C 2 With the buttons enter a set point...

Page 18: ...re value example 21 8 C is displayed 1 Press button The display shows alternately SPr and the actual temperature ramp set point changing according to the selected gradient example 42 7 C This ramp set...

Page 19: ...t1 time function and the time function Continuous operation t inf The heating is permanently active independent of the timer setting Timer operation The display shows alternately t1 time function and...

Page 20: ...Timer operation Timer not programmed or run down Press button to return to normal display actual value display automatically after approx 30 sec 6 3 2 Continuous operation 1 Press the time management...

Page 21: ...tered value The use of this time depends on the timer function selected in the user menu chap 6 4 4 5 Press button to return to normal display actual value display automatically after approx 30 second...

Page 22: ...n Timer function chap 6 4 4 Press button Setting the interface mode and if appropriate the printer interval chap 6 4 5 Figure 5 Press down button for approx 5 seconds Press button to return to normal...

Page 23: ...equired The use of temperature ramps may result in the heating up times being considerably slowed down The entry in C min or in F min meaning the nominal value gradient and limits the maximum temperat...

Page 24: ...gradient from the previously entered set point to the new one SP The actual value follows the set point value About set point display during ramp operation see chap 6 2 6 4 3 Chamber addressing If sev...

Page 25: ...set point After the defined time has expired the heating is turned off Delayed on setting 2 After the time set has passed the heating is turned on and remain in continuous operation 1 Press down butt...

Page 26: ...n button The display alternately shows PFCt and the actual setting of the interface mode 6 Set the desired interface mode with buttons Settings Modbus 0 printer 1 In case of temperature data acquisiti...

Page 27: ...ime management button The controller displays the actual time function If necessary select the time function Timer operation chap 6 3 1 In the entry level enter the desired time 3 00 chap 6 3 3 6 6 Ge...

Page 28: ...dible alarm with activated buzzer chap 8 1 by the buzzer sounding proceed as follows Disconnect the chamber from the power supply Have an expert examine and rectify the cause of the fault Restart the...

Page 29: ...safety device s regulatory function Proceed as described in chap 7 8 2 Communication software APT COM 3 DataControlSystem option The chamber is regularly equipped with a serial interface RS 422 that...

Page 30: ...perature option With this option the chamber is equipped with an analog output 4 20 mA for temperature This output permits transmitting data to external data registration systems or devices The connec...

Page 31: ...rical hazard Danger of death Damage to the internal socket Do NOT exceed the temperature set point of 90 C 194 F Set the mechanical thermostat class 3 1 to 90 C 194 F Heat emission of electrical devic...

Page 32: ...e consult BINDER Service BINDER telephone hotline 49 0 7462 2005 555 BINDER fax hotline 49 0 7462 2005 93555 BINDER e mail hotline service binder world com BINDER service hotline USA 1 866 885 9794 or...

Page 33: ...eaning products please contact BINDER service We recommend using the neutral cleaning agent Art No Art Nr 1002 0016 for a thorough cleaning Any corrosive damage that may arise following use of other c...

Page 34: ...rface disinfectants free from acid or halides Alcohol based solutions We recommend using the disinfectant spray Art No 1002 0022 For chemical disinfection we recommend using the disinfectant spray Art...

Page 35: ...hone prior to your sending the BINDER product back to us The authorization number will be issued following receipt of the information below BINDER product type and serial number Date of purchase Name...

Page 36: ...0 5 10 3 Disposal of the chamber in the Federal Republic of Germany According to Annex I of Directive 2012 19 EU of the European Parliament and of the Council on waste electrical and electronic equipm...

Page 37: ...aw Fill out the contamination clearance certificate chap 13 and enclose it with the chamber WARNING Contamination of the device with toxic infectious or radioactive substances Danger of intoxication D...

Page 38: ...ior to disposal clean all introduced or residual toxic substances from the chamber Prior to disposal disinfect the chamber from all sources of infection Be aware that sources of infection may also be...

Page 39: ...ontinuous operation chap 6 3 Semiconductor relay defective Contact BINDER service Controller defective Chamber without function only the green stand by LED is lit Chamber in stand by mode Press down t...

Page 40: ...x A b 0 1x B c 0 1 x C VUSE A 2a x B 2b x C 2c Figure 9 Determination of the useable volume The technical data refers to the defined usable volume Do NOT place samples outside this usable volume Do NO...

Page 41: ...90 600 23 62 800 31 50 1200 47 24 Depth mm inch 330 12 99 400 15 75 500 19 69 500 19 69 600 23 62 Interior volume l cu ft 53 1 9 115 4 1 240 8 6 400 14 3 720 25 7 Steam space volume l cu ft 70 2 47 14...

Page 42: ...h 11 20 33 53 80 All technical data is specified for unloaded chambers with standard equipment at an ambient temperature of 22 C 3 C 71 6 F 5 4 F and a power supply voltage fluctuation of 10 Technica...

Page 43: ...r qualified personnel authorized by BINDER perform all maintenance and repair and if components relating to chamber safety are replaced in the event of failure with original spare parts The user is re...

Page 44: ...IQ OQ PQ DL440500 Calibration service Calibration of temperature including certificate 1 measuring point DL300101 Spatial temperature measurement including certificate 9 measuring points DL300109 Spat...

Page 45: ...BF E1 05 2016 page 45 58 13 Certificates and declarations of conformity 13 1 EU Declaration of Conformity...

Page 46: ...BF E1 05 2016 page 46 58...

Page 47: ...page 47 58 13 2 Certificate for the GS mark of conformity of the VDE Pr f und Zertifizierungsinstitut Testing and Certification Institute of the Association for Electrical Electronic and Information...

Page 48: ...BF E1 05 2016 page 48 58...

Page 49: ...BF E1 05 2016 page 49 58...

Page 50: ...BF E1 05 2016 page 50 58...

Page 51: ...BF E1 05 2016 page 51 58...

Page 52: ...BF E1 05 2016 page 52 58 14 Product registration...

Page 53: ...nformation vorliegt bevor das Ger t Bauteil eintrifft Eine weitere Kopie soll dem Ger t Bauteil beigef gt sein Ggf ist auch die Spedition zu informieren Incomplete information or non conformity with t...

Page 54: ...substances weder giftige noch sonstige gef hrliche Stoffe enth lt oder solche anhaften That eventually generated reaction products are non toxic and also do not represent a hazard auch evtl entstande...

Page 55: ...n entsteht haften und BINDER gegen eventuell entstehende Schadenanspr che Dritter freistellen We are aware that in accordance with Article 823 of the German Civil Code BGB we are directly liable with...

Page 56: ...y time Take notice of shipping laws and regulations Please fill Reason for return request Duplicate order Duplicate shipment Demo Page one completed by sales Power Plug Voltage 115V 230 V 208 V 240V S...

Page 57: ..._____________________________________________________________ c ____________________________________________________________________________ 3 2 Safety measures required for handling the list under 3...

Page 58: ...all damages that are a consequence of incomplete or incorrect information provided by us and that we will indemnify and hold harmless BINDER Inc from eventual damage claims by third parties Name _____...

Page 59: ......

Reviews: