KB ECO / KB ECO-UL (E6.2) 12/2021
Page 26/85
Menu
Required access level
Functions
Service
“Service”
•
Configuration settings (only for BINDER Service)
•
Password changing for User and Admin
USB
Export: Any user
Import: “Admin”
•
Export of configuration, logger, and service data
•
Import of configuration data
Unless noted otherwise, the figure in this manual show the functional range, which is available for the user
with “Admin” authorization level
Note: When specifying the path to the respective function, the possibly required entry of a password is not
listed
5.2 Performance during and after power failures
During a power failure, all controller functions are shut down.
After the power returns, all functions return to the same status the chamber had before power failure. The
set-points are immediately resumed.
If during power failure an alarm has occurred (tolerance range, safety controller etc.), confirm the alarm.
See chap. 14.
6. Start up
After connecting the power supply, turn on the chamber by its main power switch (1). The lit pilot lamp
shows the chamber is ready for operation.
The controller shows normal display and controls temperature to the last entered values.
Warming chambers may release odors in the first few days after commissioning. This is not a quality defect.
To reduce odors quickly we recommend heating up the chamber to its nominal temperature for one day
and in a well-ventilated location.
WARNING: If customer should use a BINDER chamber running in non-supervised continu-
ous operation, we strongly recommend in case of inclusion of irrecoverable specimen or
samples to split such specimen or samples and store them in at least two chambers, if this is
feasible.
If the function “Language selection at restart” has been activated (chap. 12.5, factory setting ON), the fol-
lowing settings are checked upon start up:
•
Menu language
(chap. 12.1):
Use the
arrow buttons
to select the desired language, confirm with the
OK button
•
Temperature unit
(chap. 12.2):
Use the
arrow buttons
to select the desired temperature unit, confirm with the
OK button.
•
Current date
(chap. 12.3), format DD MM YYYY:
Use the
arrow buttons
to set the day, continue with the
OK button
.
Use the
arrow buttons
to set the month, continue with the
OK button
.
Use the
arrow buttons
to set the year, confirm with the
OK button
•
Current time
(chap. 12.4), format HH:MM:
Use the
arrow buttons
to set the hours, continue with the
OK button
.
Use the
arrow buttons
to set the minutes, confirm with the
OK button
Summary of Contents for 9020-0423
Page 72: ...KB ECO KB ECO UL E6 2 12 2021 Page 72 85 26 7 Dimensions Dimensions size 240 mm...
Page 73: ...KB ECO KB ECO UL E6 2 12 2021 Page 73 85 Dimensions size 720 mm...
Page 74: ...KB ECO KB ECO UL E6 2 12 2021 Page 74 85 Dimensions size 1020 mm...
Page 76: ...KB ECO KB ECO UL E6 2 12 2021 Page 76 85...
Page 77: ...KB ECO KB ECO UL E6 2 12 2021 Page 77 85...