11.6.6 Setup Menu/Scale/Test
Display points
✔
The number of points in the converter can
be displayed if the scale is the analogue
type.
✔
If the scale is the digital type, the number of
output points of each individual scale (scale
0-200.000) can be displayed along with the
number of points of the entire system,
obtained by calculating the average of the
points of all the cells. Each cell is identified
by a number.
Display weight
Displays the weight currently present on the
scale. On pressing the High Res. key, the
display switches to high resolution for 5
seconds. Cyclic transmission of the string
containing the weight in high resolution is
enabled on Com 2 with the protocol 9600
8-N-1.
Converter test (*)
on inserting the optional accessory board
404031, the test 0..20000div. is performed
Temperature (**)
The operating temperature is indicated
alongside the identification number of each
cell. The message
err.
will appear if the
operating temperature is not within the (-40 to
+100) °C range.
Power supply (**)
The following information is indicated
alongside the identification number of each
cell:
✔
the power supply voltage rating of the cell;
✔
the power supply voltage rating of the strain
gauge in the cell.
D450
2-61