10.4.24 Request for net weight in high resolution
YN<CR>
The reply string is:
n<SP>y<SP><um><SP><s1><s2><s3><s4><CR><LF>
n= net weight
y= net weight in high resolution
s1,s2,s3,s4=see STATUS in extended string (par. 10.2.2 on page 2-9).
10.4.25 Request for maximum capacity value
XM<CR>
The reply string is:
Max= n<SP><um><CR><LF>
10.4.26 Request for net weight without unit of measurement
YP<CR>
The reply string is:
n<CR><LF>
where:
n= significant digits of weight only
This string does not include the unit of measurement and insignificant
leading zeroes are not transmitted.
10.4.27 Lock keypad and display
LD<CR>
The message "
DISPLOCK
" is displayed in place of the weight and all
keys are disabled.
10.4.28 Unlock keypad and display
UD<CR>
The keypad and display are re-enabled.