QUICK START

  

SUREFIRE II 

 

71070  •  R3 

1/17_GB                  BIJUR DELIMON INTERNATIONAL      

     

Measurements shown in millimeters.

Dimensional Schematics

SureFire II 2, 3, 6 & 12 Litre (115 VAC, 230 VAC and 24 VDC Single Phase)

 176 

 40 

9(x4) 

 

 252 

 332 

12 Litre

 5 

 261 

 225 

243.50 

 5 

 233 

 5 

 182.50 

 215 

 5 

 153 

 5 

 5 

 188 

 184 

 Ø 7 

 Ø 7 

 Ø 9 

6 Litre

3 Litre

2 Litre

Troubleshooting

Premature wear of the gear pump and the other moving parts is usually caused by dirty or contaminated lubricant.

Failure of the PDI injectors or SLR Meter Units to deliver lubricant can be caused by an incorrect commissioning sequence, resulting in either air or dirt being 
trapped in the distribution network.

Summary of Contents for SureFire II

Page 1: ... to the user are marked by this sign All safety and or warning labels affixed to the SureFire II lubricator must be maintained in a completely legible condition Also any modifications made to the SureFire II Lubricator or to any of its components must be approved by BIJUR DELIMON prior to its use otherwise the warranty and any liability by BIJUR DELIMON will be null and void distribution network a...

Page 2: ...ear Pump Level Switch Momentary Switch Motor On Led System Relief Valve System Dump Valve Controller Assy Component Illustration SureFire II Spare Parts SureFire II Reservoir Size 2 Liter 3 Liter 6 Liter 12 Liter Part Description Part Part Part Part 24VDC Motor Kit includes driveshaft Coupling 71111 2 71111 6 71111 12 115VAC Motor Kit includes driveshaft Coupling 71112 2 71112 6 71112 12 230VAC Mo...

Page 3: ...Litre 5 261 225 243 50 5 233 5 182 50 215 5 153 5 5 188 184 Ø 7 Ø 7 Ø 9 6 Litre 3 Litre 2 Litre Troubleshooting Premature wear of the gear pump and the other moving parts is usually caused by dirty or contaminated lubricant Failure of the PDI injectors or SLR Meter Units to deliver lubricant can be caused by an incorrect commissioning sequence resulting in either air or dirt being trapped in the d...

Page 4: ...5 VAC 230 VAC max Single Phase 250cc min at 60 Hz 210cc min at 50 Hz Output Volume 24 VDC max 250cc min Output Pressure max PDI 31 bar SLR 5 bar Motor Voltage Options 100 115 VAC 50 60 Hz Single Phase 200 230 VAC 50 60 Hz Single Phase 24 VDC Motor Power Requirements 100 115 VAC Single Phase 1 0 amps 200 230 VAC Single Phase 0 70 amps 24 VDC 2 4 amps Motor Duty Cycle 100 115 VAC and 200 230 VAC S3 ...

Reviews: