14
BIJUR DELIMON INTERNATIONAL
BA_2015_2_GB_M2500G
3.
CONFIGURATION AND FUNCTION
3.4.3 Magnetic switch with reed contact and LED (also available in “Atex” design)
Fig. 14
Attaching this switch requires a piston section with movement indicator (pin).
Technical Data
Circuit diagram
Basic dimensions
LED
75
Switching current and operating voltage
Operation:
Normally open with LED
Operating voltage (Ub):
10 to 240 V AC / 170 V DC
Voltage drop:
Ub – 2.7 V
Switching current (see diagram): 0.18 A max.
Switch rating:
10 W / 10 VA max.
Contact resistance:
150 m
Switching time:
1.8 ms
Equipment temperature:
– 20
o
C to + 80
o
C
Protection type:
IP 66 (DIN 40050)
Impact strength:
50 g (during 11 ms)
Fatigue strength:
35 g (at 2000 Hz)
Connecting cable:
PVC, 2 x 0.25
Cable length:
5 m
Material: Plastic
housing
Warning:
Exceeding the specified maximum values for contact load, switching current and
switching voltage will reduce serviceable life!
“Atex” design:
Details as above with the following variations:
Ex marking:
II 3G Ex nc IIC T5 Gc X
II 3D Ex tc IIIC T120
o
C Dc IP67 X
Protection type:
IP 67 (EN60529)
Atmospheric temperature: – 20
o
C to + 50
o
C
Lock screw SW 1.5
LED