Troubleshooting
Symptom
Possible Cause
Remedy
The pump is not working or there is no
grease delivery.
Low air pressure or off.
Slowly increase the air supply pressure.
Some outlet line component is clogged
or closed.
Clean or open the outlet circuit.
The circlip (29) of the trip shoe guide is
out of its place.
Reset or replace the circlip (29).
There is an air pocket in the grease
suction inlet area.
Stir and repack the grease.
The pump begins to operate very fast.
The drum is empty or the grease level
is beneath the suction tube inlet.
Replace the drum or lower the suction
tube until the inlet reaches below the
grease level.
The pump runs on continuously after
the grease outlet is closed.
There is a grease leak in some point of
the outlet circuit.
Verify and tighten or repair.
Contamination in the upper valve or in
the foot valve.
Disassemble and clean. Replace
damaged components.
Grease is leaking through the air
outlet muffl er.
Grease has leaked to the air motor
caused by worn or damaged seals (44).
Replace the worn or damaged parts.
The air piston rod (33) is scored.
Inspect the air piston rod (33).
Replace if damaged.
Air is leaking through the air
outlet muffl er.
The quad-rings (31, 35) are worn
or damaged or scored piston assembly.
Replace quad-rings (31, 35) and/or the
piston assembly.
The air gasket (23) of the inverter
assembly is worn or damaged.
Replace the air gasket (23).