background image

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

(800) 631 0168 

TOLL-FREE   

(919) 465 0516 

FAX   

WWW.BIJURDELIMON.COM

2100 Gateway Centre Blvd., Suite 109   
Morrisville, NC 27560

35998 •  R3 

04/15

1

DP556 Pump

55:1, Air-operated, Grease

General

The DP556 Pump is a compressed air-operated reciprocating piston pump. This high capacity demand 
pump is compatible with mineral and synthetic grease and suitable for large installations with long 
length piping supplying several fl uid outlets simultaneously. This pump is mounted directly on 120 lb 
and 400 lb drums.

Operation

This pump is self-priming. To prime it the fi rst time, it is convenient to connect the air supply to the 
pump while keeping the outlet gun opened and slowly increase the air pressure by using a pressure 
regulator. Once grease starts fl owing through all the outlets, the pump is primed. The pump starts to 
pump when an outlet valve is opened, for example a grease control gun.

Technical Data

Maximum Air Pressure

140 psi (10 bar)

Minimum Air Pressure

42 psi (3 bar)

Maximum Delivery

7.25 lbs (3.2 kg/min)  

Free delivery at 100psi air inlet pressure, using NLGI #2 grease @ 70°F

Air Inlet Thread

1/2” NPT

Grease Outlet Thread

3/8” NPT

Air Piston Diameter

4.3” (110mm)

Air Piston Stroke

4-1/4” (100mm)

Installation

Mounting with Reinforced Cover 

(Recommended) 

It is recommended to install this pump on a 
drum using a reinforced cover due to weight 
considerations, but it is possible to install two 
different ways. Mount with reinforced cover (part 
#F418026 for 400 lb drum and part #F418025 
for 120 lb drum). Insert pump through the cover 
and fasten it with the enclosed screws. Insert the 
pump through the bung opening and fasten the 
cover onto the drum fi rmly.

Mounting with Cover Adapter

Mount with cover adapter (part #F360133) 
and bung bushing (part #F410001). Fasten the 
cover (part #F418026 for 400 lb drum and part 
#F418025 for 120 lb drum) onto the drum and 
screw the nut of the bung adapter securely into 
the 2” bung opening of the cover. Insert the pump 
through the nut and adjust it with the star nut to 
the desired height.

   

Always keep fi ngers and hands away from 
moving parts. Do not dent or damage the 
riser tube.

Do not ever lay the pump on the fl oor or 
allow the grease covered pump tube to 
become contaminated in order to prevent 
damage to the internal seals of the pump.   

5# '!%

5#  

Summary of Contents for DP556

Page 1: ...ree delivery at 100psi air inlet pressure using NLGI 2 grease 70 F Air Inlet Thread 1 2 NPT Grease Outlet Thread 3 8 NPT Air Piston Diameter 4 3 110mm Air Piston Stroke 4 1 4 100mm Installation Mounting with Reinforced Cover Recommended It is recommended to install this pump on a drum using a reinforced cover due to weight considerations but it is possible to install two different ways Mount with ...

Page 2: ...essure is 90 psi 6 bar An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Part Number Description A 39640 Air shut off valve B F985 Filter Regulator Lubricator C F822 Air hose D F940 Quick...

Page 3: ...8 fitting completely into the adaptor and pull clockwise first to break the seal then counter clockwise to loosen and remove it or use a pipe wrench 3 Unscrew and remove the packing set from the air motor body 4 Replace the packing set with a new one Mount the outlet adapter using Loctite Red sealer on its threads 5 Clean and lubricate the air motor components carefully Assemble the pump following...

Page 4: ...eaches below the grease level The pump runs on continuously after the grease outlet is closed There is a grease leak in some point of the outlet circuit Verify and tighten or repair Contamination in the upper valve or in the foot valve Disassemble and clean Replace damaged components Grease is leaking through the air outlet muffler Grease has leaked to the air motor caused by worn or damaged seals...

Page 5: ...1 32 Air piston F740964 36 O ring F946075 37 Air motor body F740112 38 Grease outlet F740516 39 Muffler F835400 40 Circlip F942730 42 Fixing nut packing sleeve F740563 45 Packing sleeve F740562 49 Packing sleeve holder F740517 52 Connection rod for part F624 F740545 Connection rod for part F622 F740560 53 Suction tube for part F624 F740544 Suction tube for part F622 F740559 54 Connection nut F7405...

Page 6: ... sleeve 16 Nut 17 Closing seal protection 18 Closing seal 19 Washer 21 Air gasket 23 Closing valve 24 Spring sleeve 30 Air piston rod 33 Guide ring 34 Quad ring 35 Grease packing kit lower end kit FPM6K 3 Scraper 41 O ring 43 Stop seal 44 Guide ring 46 O ring 47 O ring 48 O ring 50 Pin 51 Ball 55 Ball 56 HP Piston 57 O ring 58 Piston sleeve 59 O ring 60 Foot valve stop 62 Foot valve body 63 Step s...

Page 7: ...516 FAX WWW BIJURDELIMON COM 2100 Gateway Centre Blvd Suite 109 Morrisville NC 27560 35998 R3 04 15 7 Dimensional Schematics Part A B C F622 1105mm 43 5 640mm 25 35mm 1 4 F624 1300mm 51 835mm 33 35mm 1 4 0 2 1 08A 8 6A40B4 DC 7 4 D C8 6 0CC4A A g Measurements shown in millimeters ...

Reviews: