C-Series AS-i Master Module

General

Subject to technical modifications; no responsibility is accepted for the accuracy of this information

© Bihl+Wiedemann GmbH

7

Internet: www.bihl-wiedemann.de

Flosswoerthstr. 41

D-68199 Mannheim

phone: +49 621 33 996-0 • fax: +49 621 3 39 22 399

Is

s

ue da

te: 1

6

.4.2

015 

2.

General

2.1

Product information

This system manual applies to the following Bihl+Wiedemann GmbH equipment:

2.2

Product description and intended use

The BW3023 is an AS-interface master according to specification 3.0. It is also
backward compatible because previous specifications (2.0 and 2.1) are support-
ed as well.

It enables configuration, control and diagnosis of up to 31 single slaves or 62 A/B
slaves via LabVIEW.

Fast changing data such as I/O data or execution control flags is directly located
in the SPI frame while slower changing data and data which is only needed in
special situations is located in the command interface.

The LEDs located on the module indicate the current module status, configura-
tion errors or peripheral faults and the activity on AS-i. Diagnostics, which go far
beyond the standard diagnostics facilitate the simple detection of the occasionally
occurring configuration errors and further irritations towards the AS-i communica-
tion. So in case of an error the down time of machines can be minimized or you
can initiate preventive maintenance.

The BW3023 is suitable for use in Class I, Div. 2, Groups A, B, C, D, T4 hazard-
ous locations; Class I, Zone 2, AEx nA IIC T4, and Ex nA IIC T4 hazardous loca-
tions; and nonhazardous locations only.

2.3

Conformity statement

The C-Series AS-i Master Module has been developed and manufactured in ac-
cordance with the applicable european standards and directives.

2.4

Certification according to EN ISO 9001:2008

The manufacturer of the product possesses a certified quality assurance system
in accordance with ISO 9001.

C-Series AS-i Master Module

AS-i master module for compactRIO

BW3023

 Tab.  2-1.

Information!

The corresponding conformity statement can be found at the very beginning of
this system manual.

Information!

The current certificate can be viewed in internet:
http://www.bihl-wiedemann.de

Summary of Contents for BW 3023

Page 1: ...C Series AS i Master Module User manual Name en_system_manual_3023 pdf Revision 1 6 Revision date 2015 04 16 AS i 3 0 specification ...

Page 2: ...enerally this manual refers to products without mentioning existing patents utility models or trademarks The absence of any such references does not indicate that a product is patent free Bihl Wiedemann GmbH Flosswoerthstr 41 D 68199 Mannheim ...

Page 3: ... statement 7 2 4 Certification according to EN ISO 9001 2008 7 2 5 Bihl Wiedemann hotline 8 3 Safety 9 3 1 Intended use 9 3 2 No user serviceable parts 9 3 3 General safety information 9 3 4 Safety Guidelines for Hazardous Locations 9 3 4 1 Special Conditions for Hazardous Locations Use in Europe 10 3 5 Disposal 10 4 Technical Specifications 11 4 1 Data sheet 11 4 2 Instructions for cleaning 12 5 ...

Page 4: ...Master Module Table of contents 6 3 1 Execution Control Flags EC Flags 16 6 3 2 Slave Lists 16 7 Operating the AS i 17 7 1 Master Start Up 17 7 2 Configuration Mode 17 7 3 Examples of address assignment 19 7 3 1 Example of automatic address assignment 19 7 3 2 Example of manual address assignment 19 7 4 Abbreviations used within the Status List Control 20 7 5 Protected Operating Mode 20 8 Appendix...

Page 5: ...chnical modifications no responsibility is accepted for the accuracy of this information Bihl Wiedemann GmbH 5 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 EC Declaration of Conformity ...

Page 6: ...bol catalog 1 1 Abbreviations Information This symbol indicates important information Attention This symbol warns of a potential failure Non compliance may lead to interruptions of the device the connected peripheral systems or plant potentially leading to total mal functioning Warning This symbol warns of an imminent danger Non compliance may lead to personal inju ries that could be fatal or resu...

Page 7: ...urrent module status configura tion errors or peripheral faults and the activity on AS i Diagnostics which go far beyond the standard diagnostics facilitate the simple detection of the occasionally occurring configuration errors and further irritations towards the AS i communica tion So in case of an error the down time of machines can be minimized or you can initiate preventive maintenance The BW...

Page 8: ...Master Module General 2 5 Bihl Wiedemann hotline If problems or faults occur which you cannot rectify yourself and which are not de scribed in this user s manual please contact the Bihl Wiedemann GmbH service hotline Please make a note see lateral label of the following details before calling Bihl Wiedemann GmbH Phone 49 0 621 33 996 0 Central Fax 49 0 621 33 92 22 39 mail info bihl wiedemann com ...

Page 9: ...e danger The protection of operating personnel and the system against possible danger is not guaranteed if the control interface unit is not operated in accordance to its intended use Warning If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Warning No user serviceable parts inside Do not open Warning Safety and correct ...

Page 10: ...IC hazardous locations or in ambient temperatures of 40 C Ta 70 C you must use the device in a chassis that has been evaluated as EEx nA IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment 3 5 Disposal Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhazardous Do not remove modules unless power has been switched off or the area is kn...

Page 11: ...5 W Display LED AS i powered green on AS i voltage O K LED AS i active green AS i normal operation active LED prj mode yellow configuration mode active LED config error red on at least 1 configured AS i slave is missing or at least 1 detected AS i Slave is not configured or for at least 1 configured and detected AS i slave the actual configuration data does not match the nominal configuration data...

Page 12: ...tructions for cleaning If you need to clean the module wipe it with a dry towel Attention Provision shall be made to prevent the rated voltage being exceeded by the transient disturbance of more than 140 of the peak rated voltage The system shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN60529 and used in an enviro...

Page 13: ...ription AS i powered Green AS i Master power Peripheral fault AS i active Green Normal operation active prj mode Yellow Configuration state config error Red Config error occurred Tab 5 2 AS i Master max 5 A PELV according to EN 50178 Protective extra low voltage AS i power supply AS i Slave AS i Slave AS i Master max 8 A PELV according to EN 50178 Protective extra low voltage AS i power supply AS ...

Page 14: ...g Elements PINs 0 1 AS i AS i Connection AS i circuit 2 3 AS i PWR AS i PWR Supply voltage AS i circuit 4 FE Functional earth LEDs 3 config error Configuration error At least one configured slave is missing at least one detected slave is not projected or for at least one projected and detected slave the actual con figuration data does not match the nominal configuration data 0 AS i powered The AS ...

Page 15: ...ction Carrier to Module Direction Carrier from Module 0 16 Reserved Reserved 16 32 Output Data Image ODI Input Data Image IDI 48 256 Analogue Output Data Image AODI Analogue Input Data Image AIDI 304 2 Reserved Execution Control Flags EC Flags 306 2 Reserved Reflected HI Flags 308 8 Reserved List of active slaves LAS 316 8 Reserved List of detected slaves LDS 324 8 Reserved List of projected slave...

Page 16: ...neReady Pok PeriperyOk 6 3 2 Slave Lists AODI AIDI Adresse 215 214 213 212 211 210 29 28 27 26 25 24 23 22 21 20 0x00 Slave 0 1st Channel 0x02 Slave 0 2nd Channel 0x7E Slave 15 4th Channel 0xFE Slave 31 4th Channel Tab 6 5 EC Flags Address 215 214 213 212 211 210 29 28 27 26 25 24 23 22 21 20 0x0 Pok OR APF NA CA AAv AAs S0 Cok Tab 6 6 LAS LDS LPS LPF Address 215 214 213 212 211 210 29 28 27 26 25...

Page 17: ...in section Configuration Mode some LED s should turn ON depending on the state of master 1 If the AS i network is not sufficiently powered 2 If the AS i network is sufficiently powered On the VI Frontpanel press the the Operation Mode switch and notice your modules being marked in the address table then press the Store Actual Configuration button to turn OFF the Config Error LED 7 2 Configuration ...

Page 18: ...perly by right clicking the target within your project and going to Connect 4 Open the front panel of the BW3023 AS i Commissioning vi Assigning an AS i Address in the Configuration Mode Assigning a Slave Address 1 Connect a new slave in the AS i network the state of this slave is showed in the Slave List indicator 2 Select the devices old address within the Old Address control 3 Select the new ad...

Page 19: ... delete the address from the module Automatic Address Assignment shall be processed only if 1 the Master module execution control mode is the protected mode 2 the Auto_Address_Enable mode is ON 3 the Auto_Address_Assign mode is set and If one and only one configured slave is not detected 7 3 Examples of address assignment 7 3 1 Example of automatic address assignment 1 Select an existing Slave e g...

Page 20: ... slaves LDS and members of the list of projected slaves LPS and whose configuration data image CDI value equals the permanent configuration data PCD value for that specific slave 1 Follow steps 1 5 of section Configuration Mode to bring the AS i network to Configuration mode 2 Click the Operation Mode control to change to Protected Mode X O K The configuration data for the detected AS i slave matc...

Page 21: ...in 8 bytes 389002 asiErrorAnalogOpera tionTimeout Analog read or analog write timed out Solution Increase timeout and ensure AS i Commit vi has been called 389003 asiErrorCommandInval idRequestLength Command request size is out of range Solution Make sure the length of command request is smaller than 39 bytes 389004 asiErrorCommand Timeout Timeout occurred waiting for the command response Solution...

Page 22: ...owing page and fax it to us or send your remarks sug gestions for improvement etc to the following address Bihl Wiedemann GmbH Technical Support Floßwörthstr 41 D 68199 Mannheim Germany Phone 49 0 621 33 99 6 0 Fax 49 0 621 33 9 22 39 eMail mail bihl wiedemann de Fax reply Bihl Wiedemann GmbH Date Technical Support Fax No 49 0 621 33 9 22 39 eMail mail bihl wiedemann de From Firm Name Dept Street ...

Page 23: ...ormation Bihl Wiedemann GmbH 23 Internet www bihl wiedemann de Flosswoerthstr 41 D 68199 Mannheim phone 49 621 33 996 0 fax 49 621 3 39 22 399 Issue date 16 4 2015 Content Yes Partly No Are the formulations technical terms understandable Are the examples relevant Is the Manual easy to handle Is there important information missing If yes explain Comments ...

Page 24: ......

Reviews: