Fig. 10.1
ELECTRICAL FEEDER CABLE CONNECTION
To connect the feeder cable to the cooker it is necessary to:
– Remove the screw that hold shield “A” behind the cooker (fig. 10.1).
– Open completely the cable clamp “D”.
– Insert the feeder cable of the suitable section (as described in the next chapter) into
the cable clamp “D”.
– Connect the phase, neutral and earth cables to
the terminal block “B” according to the diagram
in figure 10.2.
– Pull the feeder cable and block it with cable
clamp “D”.
– Re-mount shield “A”.
Connecting the power cord must be entrusted to skilled personnel in accordance
with the instructions supplied by the manufacturer and in compliance with
established safety standards.
FEEDER CABLE SECTION
“TYPE H05RR-F OR H05VV-F”
230 V
3 x 6 mm
2
(**)
(**)
– Connection with wall box connection.
– Diversity factor applied.
– A diversity factor may be applied to the total
loading of the cooker only by a suitable
qualified person.
PE
1 2 3 4 5
N (L
2
)
L
1
230 V
2
3
4
5
1
230 V ~
N(L
2
)
PE
L1
Red
or
Brown
(Live)
Black
or
Blue
(Neutral)
Green
and
Yellow
(Earth)
PE
Earth
N
Neutral
L
Live
Fig. 10.2
Fig. 10.3
A