background image

 

 

Avoid  pointing  the  detector  towards  objects  that  may  move  in  the  wind,  such  as  curtains 

plants etc. 

 

 

 

CONNECTION:                                                                                                                                                           

 

                   

Warning. Danger of death through electric shock! 

 

Must be installed by professional electrician, 

 

Disconnect power source. 

 

Cover or shied any adjacent live components. 

 

Ensure device cannot be switched on. 

 

Check power supply is disconnected. 

  Loosen the screw on the bottom and remove back cover plate. 

  Pass the power wire through the hole with gasket in the bottom. Connect the power wire into 

connection-wire column according to the connection-wire diagram. 

  Fix the back cover plate with screw to the wall. 

  Screw sensor back onto cover plate. 

 

 

 

 

 

 

Figure1                                                                        Figure2 

CONNECTION-WIRE DIAGRAM:                                                                                                                                     

 

 

 

 

 

 

 

TEST:

                                                                                                                                                               

 

 

Turn  the  LUX  knob  clockwise  to  the 

maximum  (sun).Turn  the  TIME  knob 

anti-clockwise on the minimum (10s). 

  Switch the sensor on. After Warm-up 30sec, the sensor is stable and ready to operate .If 

the sensor receives a motion signal, the output will turn on and start timing out as per the 

trim pot settings.

 

 

  Turn  LUX  knob  anti-clockwise  to  the  minimum  (moon).  If  the  ambient  light  is  more  than 

3LUX, the sensor would not work and the output will turn off. 

Note:  when  testing  in  daylight,  please  turn  LUX  knob  to          (SUN)  position,  otherwise 

the sensor will not switch on! 

FAULT FINDING:                                                                                                             

 

The load does not turn on: 

a. check if the connection of power source and load is correct. 

b. check if the settings of working light correspond to ambient light. 

 

The sensitivity is poor: 

a. check if there is any object in front of the detector that blocks the sensor receiving 

signals. 

b. check if the ambient temperature is close to 37 deg. 

(human body temperature)

 

c. check if the sensor head is orientation in the correct position. 

 

 

 

 

 

 

 

 

 

 

CE    compliance    IEC 17025 

www.bigideascompany.com.au

 

 

Reviews: