45
WWW.BIGASSFANS.COM ©2012 DELTA T CORP. DBA BIG ASS FAN ALL RIGHTS RESERVED
12’–24’ POWERFOIL
®
8, 12’–24’ POWERFOIL
®
8 PLUS
Troubleshooting
General troubleshooting
Some issues can be resolved before requesting service. Review the below troubleshooting tips before contacting Customer Service for
support.
Symptom
Possible solution(s)
The fan is turning in the wrong direction.
To be effective, the fan should be rotating in the counterclockwise direction when viewed
IURPWKHÀRRU,IWKHIDQLVQRWURWDWLQJLQWKHFRXQWHUFORFNZLVHGLUHFWLRQSUHVVWKH)5
button on the controller.
A popping noise is coming from the fan.
Airfoil noise comes from airfoils that are
QRWWLJKWHQHGWRWKHVSHFL¿HGWRUTXH
Disconnect the fan from power, and then tighten the airfoil fasteners to 29 ft·lb
(39.3 N·m). If the popping still occurs, verify that the airfoils are not contacting each
other. If they are, contact Big Ass Fans Customer Service at 1-877-BIG-FANS.
The fan will not start.
9HULI\WKHIROORZLQJ
Make sure that all wires are securely connected.
9HULI\WKDWVXSSO\SRZHULVDGHTXDWHDQGIXQFWLRQDO
If the fan still does not start, contact Customer Service at 1-877-BIG-FANS.
The fan controller generates radio
IUHTXHQF\QRLVH5)
Fan controllers generate RF noise in many
ways, but this can be prevented using
the proper wiring practices outlined in
“Electrical Installation” (p. 25).
9HULI\WKHIROORZLQJ
Do not run your controller and sensitive equipment on the same power line.
Ensure proper grounding at the motor, controller, and from the controller to the utility.
If the noise is still present, contact Customer Service at 1-877-BIG-FANS.
The motor makes noise when fan speed is
increased.
Audible high frequency carrier noise may
be an indicator of a stall condition.
9HULI\PRWRUFXUUHQWVDUHZLWKLQOLPLWV6HHWKHIDQVSHFL¿FDWLRQVRQSDJH
The fan wobbles during operation.
9HULI\WKDWWKHPRXQWLQJVWUXFWXUHLVULJLGHQRXJKWRVXSSRUWWKHIDQDQGWKDWWKHIDQLV
not being exposed to external air forces.
,IJX\ZLUHVZHUHLQVWDOOHGFRQ¿UPSURSHULQVWDOODWLRQ,IJX\ZLUHVZHUHQRWLQVWDOOHG
contact Big Ass Fans Customer Service at 1-877-BIG-FANS.
Note: Some motor, gearbox, or drive noise is to be expected and is normal.
Cutting the extension tube
CAUTION: Ensure the safety cable is not damaged after cutting and drilling the extension tube!
ATTENTION : S’assurer que le câble de sécurité n’est pas endommagé après avoir coupé et percé le tube de rallonge.
If your mounting structure requires a non-standard extension tube length, use the below guidelines to cut the extension tube.
LENGTH
TOP END
BOTTOM END--
CUT THIS END ONLY
IMPORTANT
SAFETY CABLE IS ATTACHED
HERE-- DO NOT CUT OR ALTER
Ø0.56” (1.4 cm)
9/16” or 7/32” Drill Permissible
0.78”
(1.98 cm)
0.78”
(1.98 cm)
3”
(7.62 cm)
3”
(7.62 cm)
1.5”
(3.8 cm)
1.5”
(3.8 cm)
2.8”
(5.79 cm)
3”
(7.62 cm)
3”
(7.62 cm)
Summary of Contents for Powerfoil 8 Plus