Appendix D: ICON3000
Ex db eb h IIC T4 Gb / Ex h tb IIIC T135°C Db IP66/68
Ex db eb h ia IIC T4 Gb / Ex h tb IIIC T135°C Db IP66/68
D.1
Safety Instructions
D.1.1
General
This Appendix D is supplemental to Installation, Operation, and Maintenance Manual
MAN-02-04-97-0713 and prescribes the safety instructions applicable to electric actuators
ICON3000-010, ICON3000-020, and ICON3000-030, either as a base unit or when they are
equipped with:
a.
an additional entry mounted on the control compartment or when they
are equipped with an optional extension
b.
additional entries
c.
an optional electronic card mounted on the terminal board compartment
The subject actuator is certified according to IEC/EN 60079-0, 60079-1, 60079-7,
60079-11 and 60079-31 standards, with protection type Ex db eb h IIC or Ex db eb h ia IIC
for gas and Ex h tb IIIC for dust, suitable for installation in an ambient temperature range
from -25 °C (-13 °F) to +60 °C (+140 °F).
WARNING
Installation, configuration, commissioning, maintenance, and repairs must be performed
by approved and qualified personnel only.
The ICON3000 is designed in accordance with the applicable international rules and
specifications, but the following regulations must be observed in every case:
•
General installation and safety regulations.
•
The proper use of personal protective devices (glasses, clothing, gloves).
•
The proper use of tools, lifting equipment, and transport equipment.