Installation, Operation and Maintenance Manual
MAN 689 Rev. 6
June 2021
Operation and Use
Position
indicator
(index)
Pin
If the index (Figure 20), does not signal the proper position of the valve but is turned
by 90°:
•
Remove the roll pin placed on the position indicator (index).
•
Turn the indicator until reaching its proper positioning.
•
Put the roll pin back in its position.
NOTICE
End of stroke microswitches should be operated before the stop of the stroke of the
actuator due to mechanical stops. Adjust the relative cams properly.
Figure 17
Position indicator and pin for microswitches box
21