Bierer DCI-50-CT Operating Instructions Manual Download Page 6

 

 

IDENTIFY URD CABLE USING AVR RECEIVER 

 
The AVR receiver is a passive audio/visual receiver that will indicate single 
light or single beep to indicate the correct cable. 

 
1.

 

Follow the “DC TRANSMITTER SET-UP AND TEST” Procedure 
outlined on page 4. 

2.

 

Ensure the power light is on, the blue pulse light is pulsing, and the 
green short continuity light is illuminated. If the red open light is on, 
turn the unit off, check your connections and try again. 

3.

 

Plug the CT into the AVR receiver. 

4.

 

Clamp the CT around the cable at the source so the red arrow faces 
away from the transmitter on the cable. (Pointing towards the grounded 
end of the cable.) 

5.

 

Adjust the sensitivity knob till a clear positive indication is observed. 

6.

 

The Receiver will indicate a beep or blinking if the unit is installed 
correctly. 

7.

 

At the test site, Clamp the CT onto the cable so the red arrow points to 
the grounded end of the cable. 

8.

 

The correct cable will indicate either a beep or blinking light. 

9.

 

All other cables should have no indication. If more than one positive 
indication is detected, reverse the clamp and test again. 

10.

 

After testing is complete remove all equipment and restore cable to its 
original condition. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Summary of Contents for DCI-50-CT

Page 1: ...1 Operating Instructions DCI 50 CT Cable Identifier...

Page 2: ...Liability Bierer Associates Inc warrants this product to be free from defects in workmanship and material under normal use and service conditions for a period of one year from date of shipment Due to...

Page 3: ...MAN HOLE OR DITCH ODD MAN OUT DCI 50 RED LEAD BLACK LEAD DCI 50 H1B H1A X1 X3 X2 H1B H1A TRANSFORMER SWITCH GROUNDED FAR END MAN HOLE OR DITCH ODD MAN OUT H1A H2A H3A H1B H2B H3B SIGNAL MOVING IN OPP...

Page 4: ...he battery before operation 3 Install the battery to the unit by sliding the battery into the battery holder 4 Make sure the alligator clips are not touching and turn the unit on 5 The power and open...

Page 5: ...on and place the tip on the wire close to the transmitter to verify cable and direction of the pulse 4 At the test site slowly approach the cable with the tip of the STRCV And identify the cable with...

Page 6: ...around the cable at the source so the red arrow faces away from the transmitter on the cable Pointing towards the grounded end of the cable 5 Adjust the sensitivity knob till a clear positive indicat...

Page 7: ...es away from the transmitter on the cable Pointing towards the grounded end of the cable 5 If the red cable is attached to the center conductor and the black cable is attached to the ground the needle...

Page 8: ...to unit 1 With power off of the unit plug the CT into the back of the transmitter 2 Clamp the CT around the neutral between the cable and the common neutral The unit will do the rest 3 When removing...

Reviews: