FEATURES

3

Please read the entire manual and fully understand the

proper operating procedures before proceeding to use 

the press

.

1. Place the vacuum press in either a BIENFANG

® 

Floor

Stand or a sturdy, flat, level surface and ensure the

feet and hinges are properly adjusted. The press should

not be located in the direct path of air conditioning or

room-cooling vents.

2. Keep the vent cloth positioned so that it covers the

vacuum manifolds (located in the rear corners of the

press) and does not extend across the edge of the 

rubber diaphragm. Failure to do so will result in tempo-

rary loss of vacuum.

3. Place all materials inside the press so that they fit into

the recessed chamber in the base. If any materials

extend across the edge of the rubber diaphragm, they

will prevent a seal and cause either low vacuum or no

vacuum at all.

4. When opening and closing the press grasp both han-

dles and keep your body, head and hands away from

the press opening.

5. Foreign objects such as knives, tools, rulers, paper

clips and markers should be kept out of the press and

away from the press opening at all times.

6. Do not stack boards in the press. Placing a smaller

board on top of a larger one may cause lines or dents

in the aluminum platen.

7. Do not use an exposed blade to cut materials in the

press. A slice or puncture in the rubber diaphragm will

result in loss of vacuum.

8. Allow the vacuum level to drop before opening the

press.

9. Turn the power breaker OFF and keep the press in the

closed position when not in use. Disconnect the power

supply before cleaning or replacing parts.

10. High-pressure gas springs make opening and closing

the press easier. If they are to be removed, the top

MUST be held in the fully opened position for safety

and to prevent damage.

Contact your authorized Hunt dealer or Hunt Technical

Service in the event the press needs service for parts not

covered in this Owner’s Manual.

IMPORTANT SAFEGUARDS

The Bienfang

® 

Vacuum Press 3648H, 4468H and 5298H 

presses are professional mounting and laminating systems

designed to provide the highest quality results with maximum

versatility and ease of operation. The combination of two

machines in one – a dry mount press and cold vacuum frame –

allows the quick professional application of dry mounting adhe-

sives and laminates, as well as wet and spray adhesives. The

presses decrease labor costs and increase production while

minimizing operator training and supervision.

Specific features and benefits include:

• Easy to Use: Close the top, press a key and wait for the

signal that the work is done - automatic operation frees

the operator for other duties.

• Digital Display: lets the operator know at all times the 

vacuum level, platen temperature and cycle time remain-

ing; the display is switchable between showing the original

settings and actual readings.

• Locking: All current models have side latches. Previous

models have the front latch.

• Programmable Settings: The operator can store up to six

programs in memory for repeatable processes.  Time and

temperature settings for each program are stored for

quick, easy access.

• High, Uniform Vacuum Pressure: 10-13 psi (20-27" Hg)

ensures good bond penetration for consistent, professional

results.

• Automatic Pressure Adjustment: Self adjusts for boards up

to 1" thick, or mounts several pieces of varying thickness

at one time — without additional set-up time.

• Double-Duty Top: Specially constructed heavy-duty flat top

doubles as work or storage space when the press is not 

in use.

• Floor Stand: Optional for 3648H and 4468H. Used to

make the presses freestanding units rather than tabletop

machines. Each incorporates one shelf support. The

5298H model comes with a floor stand.

Summary of Contents for Vacuum Press 3648H

Page 1: ...Instruction Manual Provided By http www MyBinding com http www MyBindingBlog com BIENFANG 3648H 4468H 5298H VACUUM PRESS...

Page 2: ...Bienfang Vacuum Press 3648H 4468H and 5298H Programmable Combination Vacuum Presses OWNERS MANUAL...

Page 3: ...468H 3648H Catalog Number 2170 2160 2180 Floor Stand included 2165 2167 Working Area 48 x 96 x 1 44 x 68 x 1 36 x 48 x 1 Outside Dimensions 109 x 65 x 7 77 x 57 x 7 57 x 48 x 1 Net Weight 375 lbs 215...

Page 4: ...fety and to prevent damage Contact your authorized Hunt dealer or Hunt Technical Service in the event the press needs service for parts not covered in this Owner s Manual IMPORTANT SAFEGUARDS The Bien...

Page 5: ...se with Neutral on a 20 Amp circuit Actual line voltages between 208 230 VAC are acceptable The press power cord has a NEMA L14 20P twist lock plug which is UL listed for use in this application The 5...

Page 6: ...that the frame of the press is level both front to back and side to side If not on a floor stand adjust the corner feet until the press is level Hinge Adjustment After leveling the press check the adj...

Page 7: ...x 30 yds for 3648H 4468H Bienfang No 986 50 x 36 yds for 5298H Release Board a thin smooth board coated with silicone on both sides Lays flat to smooth out posters doesn t wrinkle or crease so it last...

Page 8: ...urn off automatically because materials could be accidentally left inside the press with out pressure while they are still hot This could cause delaminating or excessive warping of the mounting board...

Page 9: ...emem bered even after turning the press off To change the settings of an existing program press Program the keypad number and then the appropriate Set key numeric entry and Enter Press Enter a second...

Page 10: ...key Watch the press temperature rise and when it reaches the bonding tempera ture allow an additional 1 4 minutes depending upon the size and type of material processing time Note the complete cycle...

Page 11: ...materials or workmanship within the applicable warranty period will be repaired or at our option replaced without charge upon its return postpaid as outlined below The applicable warranty shall be one...

Page 12: ...Inadequate time Reprocess longer High moisture level Reprocess longer Low uneven pressure See low vacuum Low high temperature Check specifications Checking the Pump and Fittings To check attachment of...

Page 13: ...25 TS1105025 Breaker 2 Pole Domestic Intn TS1308041 TS1308041 TS1308061 Control Board Assembly Domestic TS2304093 TS2304093 TS2304093 International TS2304093 1 TS2304093 1 TS2304093 1 R bbon Cable Int...

Reviews: