Before using the product, please read the In-

structions for Use carefully. You can download 

it on the internet: 
www.bienair.com/support/download-center/

If you have any difficulty accessing the docu

-

ment or would like to request a printed copy, 

you can order one - free of charge - by con-

tacting one of Bien-Air subsidiary (see phone 

numbers at the back cover of the Instructions 

for Use).
The printed copy of the instruction for use will 

be provided within a maximum of 5  working 

days. 
Note: The Instructions for Use may be revised 

from time to time. Please refer to Bien-Air web 

page for the most recent version. 

Lesen Sie vor dem Gebrauch des Produkts 

die Bedienungsanleitung sorgfältig durch. 

Diese können Sie unter folgendem Link herun-

terladen: 
www.bienair.com/support/download-center/

Sollten Sie Probleme beim Zugriff auf das 

Dokument haben oder eine gedruckte Ver-

sion bevorzugen, können Sie diese bei einer 

Niederlassung von Bien-Air oder über die 

Bien-Air-Zentrale in der Schweiz kostenfrei 

bestellen. Die Telefonnummern finden Sie auf 

der Rückseite der Bedienungsanleitung.
Die Druckversion erhalten Sie dann innerhalb 

von fünf Werktagen.
Hinweis: Die Bedienungsanleitung wird von 

Zeit zu Zeit überarbeitet. Auf der Website von 

Bien-Air finden Sie immer die aktuelle Version.

Avant d’utiliser le produit, veuillez lire atten-

tivement le mode d’emploi. Vous pouvez le 

télécharger sur Internet:
www.bienair.com/support/download-center/

Si vous rencontrez des difficultés pour ac

-

céder au document ou si vous souhaitez en 

demander une copie imprimée, vous pouvez 

en commander une gratuitement en contac-

tant l’une des filiales de Bien-Air ou le siège 

social de Bien-Air en Suisse (voir numéros de 

téléphone au dos du mode d’emploi).
La copie imprimée du mode d’emploi sera 

fournie dans un délai maximum de 5 jours 

ouvrables.
Remarque: Le mode d’emploi peut être révisé 

de temps à autre. Veuillez vous référer à la 

page Web de Bien-Air pour la version la plus 

récente.

IT

ES

RU

Prima di utilizzare il prodotto, leggere at-

tentamente le istruzioni per l’uso. È possibile 

scaricarle su internet: 
www.bienair.com/support/download-center/

Nel caso si riscontrino difficoltà nell’accedere 

al documento o si desideri una copia cartacea, 

è possibile ordinarla gratuitamente contat

-

tando una filiale Bien-Air o la sede centrale 

di Bien-Air in Svizzera (consultare i numeri di 

telefono sul retro della copertina delle istruzi-

oni per l’uso).
La copia cartacea delle istruzioni per l’uso 

sarà fornita entro un massimo di 5 giorni 

lavorativi.
Nota: Le istruzioni per l’uso possono essere 

revisionate di volta in volta. Fare riferimento 

alla pagina web Bien-Air per la versione più 

recente.

Antes de utilizar el producto, lea atentamente 

las instrucciones de uso. Puede descargarlas 

en: 
www.bienair.com/support/download-center/

Si tiene alguna dificultad para acceder al doc

-

umento o quiere solicitar una copia impresa, 

puede pedirla de manera gratuita poniéndose 

en contacto con una de las filiales de Bien-Air 

o con la sede de Bien-Air en Suiza (consulte 

los números de teléfono en la cubierta trasera 

de las instrucciones de uso).
La copia impresa de las instrucciones de uso 

se proporcionará en un plazo máximo de 5 

días laborables.
Nota: Las instrucciones de uso pueden 

revisarse periódicamente. Consulte la página 

web de Bien-Air para ver la versión más reci-

ente.

Перед использованием изделия 

внимательно прочтите Инструкцию по 

эксплуатации. Ее можно загрузить из 

интернета: 

www.bienair.com/support/download-center/

Если у вас возникнут сложности с доступом 

к документу или вы захотите заказать 

напечатанный экземпляр (бесплатно), 

обращайтесь в одну из дочерних компаний 

Bien-Air или в главный офис Bien-Air в 

Швейцарии (номера телефонов приведены 

на задней странице обложки Инструкции по 

эксплуатации).
Напечатанный экземпляр Инструкции по 

эксплуатации будет предоставлен в течение 

максимум 5 рабочих дней.
Примечание. Инструкция по эксплуатации 

может время от времени пересматриваться. 

Новейшая версия будет опубликована на 

веб-странице Bien-Air.

PL

ZH

Przed przystąpieniem do użytkowania pro

-

duktu należy uważnie zapoznać się z Instruk

-

cją użytkowania. Instrukcję można pobrać ze 

strony: 
www.bienair.com/support/download-center/

W przypadku trudności w dostępie do doku

-

mentu lub w celu zamówienia (darmowego) 

drukowanego egzemplarza należy skon

-

taktować się z jednym z oddziałów Bien-Air 

(numery telefonów podano na tylnej okładce 

Instrukcji użytkowania).

Drukowany egzemplarz instrukcji zostanie 

dostarczony w ciągu maksymalnie 5 dni robo

-

czych. 

Uwaga: Od czasu do czasu Instrukcja użytko

-

wania może być poddawana modyfikacjom. 

Najnowsza wersja dostępna jest na stronie 

internetowej Bien-Air. 

使用本产品之前,请仔细阅读使用说明书。您

可以通过以下网址进行下载 : 

www.bienair.com/support/download-center/

如果您获取该文档有困难或希望索取印刷版,

则只需联系任意 Bien-Air 子公司或位于瑞士的 

Bien-Air 总部(电话号码位于使用说明书的封

底),即可免费获取。
印刷版的使用说明书将在最多 5 个工作日内提

供。
注意 :使用说明书可能会不时修订。如需最新

版本,请访问 Bien-Air 网站。

Summary of Contents for Lubricare 2 HIM-2

Page 1: ...Dental Handpiece Maintenance Device Distributed by Bien Air Dental SA Manufactured by J MORITA MFG CORP 2021 05 21 Pub No K345 91001 503 EN Printed in Japan Lubricare 2 INSTRUCTIONS FOR USE...

Page 2: ...r cente IT ES RU Prima di utilizzare il prodotto leggere at tentamente le istruzioni per l uso possibile scaricarle su internet www bienair com support download center Nel caso si riscontrino diffico...

Page 3: ...s manual thoroughly before using the device and pay close attention to warnings and cautions Keep this manual in a readily accessible place for quick and easy reference Trademarks and Registered Trade...

Page 4: ...allation 12 6 1 2 Air Tube 13 6 1 3 Power Cord 14 6 2 Spray Cans 15 6 2 1 Spray Stands 16 6 2 2 Spray Cans 17 6 2 3 Spray Stand Adjustment 18 6 3 Couplings 19 6 4 Oil Absorbent Sheet 20 6 5 Oil Collec...

Page 5: ...r 32 8 2 2 Air Regulator 32 8 3 Parts Replacement 33 8 3 1 Oil Absorbent Sheet 33 8 3 2 Oil Absorbent Pad 33 8 3 3 Door Oil Absorbent Sheet 33 8 3 4 Nozzle Skirt 34 8 3 5 Coupling O rings 34 8 3 6 Spr...

Page 6: ...fessionals Do not use the Lubricare 2 for purposes other than lubrication and flushing as part of handpiece maintenance The term flushing as used in this manual means ejecting and removing cutting deb...

Page 7: ...d trained technician authorized by the manufacturer For customers who use the Lubricare 2 in the EU If any serious incident occurs in relation to the device report it to a competent authority of your...

Page 8: ...tal SA OF FICE To prevent infection always wear appropriate personal protective equipment such as surgical gloves when using or cleaning the device These precautions are especially critical for safe o...

Page 9: ...d Lubrication Packing Inspection Maintenance Procedure Sterilization Cleaning and Lubrication The term cleaning used in this manual refers to an internal cleaning of the handpiece with SPRAYNET that i...

Page 10: ...Absorbent Pad Qty 1 Oil Absorbent Sheet Qty 1 Spray Stands Qty 2 Power Cord Qty 1 Air Tube Qty 1 Door Oil Absorbent Sheet Qty 1 Cord type and plug shape depend on your country or region Front Door Sh...

Page 11: ...r View Air Regulator Rear Cover R Rear Cover L Spray Stand Power Cord Front View Couplings sold sepa rately Chuck Lubri cation Unit Exhaust Opening Front Door Door Hinge Door Oil Absorbent Sheet Botto...

Page 12: ...xcess oil inside the hand piece when the maintenance is completed Start Stop Switch Mode 1 Selection Switch Press this switch to start or stop cleaning or lubrication Press this switch to select Mode...

Page 13: ...handpiece lubrica tion is in progress Line Selection Lamps Each lamp lights up when the corre sponding line is selected When perform ing the lubrication the corresponding line lamp will blink When th...

Page 14: ...a well ventilated place and ventilate it regularly 6 1 Main Unit 6 Setup Install the main unit with at least the clearance shown below provided around the unit Place the device on a level and stable s...

Page 15: ...the air tube a light tug to make sure it is properly connected Then supply air by opening the main air valve Do not give the air tube a hard pull Otherwise the unit may tip over Make sure that the air...

Page 16: ...Power Cord Plug Power Cord Connector Power Cord Hole Power Cord Connector 4 Pull up the adjustment dial of the air regulator and then rotate it to adjust the air pressure between 0 3 MPa and 0 5 MPa...

Page 17: ...e Lubricare 2 can be used with sprays other than those made by Bien Air Dental SA To do this the stand for the spray can and the coupling must be replaced Spray Cans and Cleaning and Lubrication Lines...

Page 18: ...Check the spray can volume and make sure the protrusion hub in the middle of the spray stand is correctly facing up or down de pending on the spray can as shown in the table below and then set it str...

Page 19: ...g handpieces Doing so will damage the Lubricare 2 and handpieces Make sure the lock levers are all the way up Otherwise improper connection results in not supplying oil The corresponding Empty Spray C...

Page 20: ...e height rotate the adjusting screw located in the center of the spray stand with a hex wrench 1 Turn the lock lever down in clockwise direction 2 Check that the lock lever is horizontal and then remo...

Page 21: ...matched Set the coupling s thick pipe to the right side and in sert the coupling into the connector p 10 5 2 1 Recommended Mode 2 Push the coupling against the connector with one hand and pull down t...

Page 22: ...is oriented towards the front side of the unit The sheet can be installed either way up Oil Absorbent Pad Oil collection tray is not properly inserted Oil Collection Tray Oil Absorbent Sheet Shorter L...

Page 23: ...place Magnets Front Door Front Door Line up the magnets with the metal bumps of the sheet stopper Front Door Sheet Stopper Door Oil Absorbent Sheet 1 Insert the front door sheet stopper into the door...

Page 24: ...d Micromotor Attachment speed increase Chuck Lubrication daily use Chuck maintenance performed before handpiece body lubrica tion Approx 4 sec p 25 7 3 3 Chuck Lubrica tion Handpiece Body Cleaning Lub...

Page 25: ...ines 1 to 4 are set for Mode 1 Check the handpiece type and change the mode as neces sary p 10 5 2 1 Recommended Mode p 19 6 3 Couplings p 28 7 3 5 Switching Maintenance Mode 7 3 2 Handpiece Body Clea...

Page 26: ...e Start Stop Switch The Line Selection Lamp for the current cleaning process will blink and the lamps for the reserved lines will light up Press the Start Stop Switch again to stop the process Do not...

Page 27: ...o not remove the handpiece from the chuck nozzle until you hear the single sustained beep Otherwise it may result in excessive scattering of oil If the nozzle skirt comes off be sure to reinstall it a...

Page 28: ...d for Line 1 To cancel the line selection press the Line Selection Switch again The Line Selection Lamp will go out 2 Starting Lubrication Face the bur insertion hole towards the main unit If the bur...

Page 29: ...g the operation This will result in oil leakage and malfunction Do not block the exhaust opening or the exhaust outlet on the bottom of the unit Otherwise the front door will open during the maintenan...

Page 30: ...ired Line Selection Switch and press the Start Stop Switch for about two seconds until you hear a single sustained beep The Line Selection Lamp and currently set Lubrication Mode Selection Lamp will b...

Page 31: ...from inside the handpiece 2 Hold down the Line Selection Switch for the line where the handpiece is attached Air Blow Mode starts after approximately two seconds You can release the switch when the p...

Page 32: ...ound and the Line Selection Lamp for the completed line and the Completion Lamp will light up Wipe excess oil from the handpiece with a soft cloth or gauze after the maintenance 3 Check that the selec...

Page 33: ...Door Sheet Stopper Order parts from your local dealer or Bien Air Dental SA OFFICE Reinstall all parts after cleaning Do not use disinfectants that contain chlorine based cleaners or benzalkonium chlo...

Page 34: ...a problem with the air compressor and it may result in poor maintenance Contact your local dealer or Bien Air Dental SA OFFICE p 13 6 1 2 Air Tube Air Regulator Front Door Hold the device firmly with...

Page 35: ...d with excessive oil absorption Doing so could cause more oil mist to come out from the device and spray into your eyes Dispose of used door oil absorbent sheets according to regulations for medical w...

Page 36: ...rings 8 3 6 Spray Cans 1 Remove the old O rings with a pair of tweezers or another such tool 2 Set the new O rings according to coupling grooves Replace the can when the corresponding Empty Spray Can...

Page 37: ...rt the hinge straight until it snaps on p 32 The door seal is partially removed Reinstall the door seal properly N A Process stops before lubri cation Selected Line Selection Lamp and corresponding Em...

Page 38: ...the lamp still lights up even after performing maintenance again have the device repaired N A Oil seeps out excessively from the connection parts and the handpiece head during normal use of the handpi...

Page 39: ...on rm that the device is uncontaminated and must then have it disposed of by a healthcare facility or an agent licensed and quali ed to handle standard industrial waste and industrial waste requiring...

Page 40: ...38 Oil Absorbent Pads Qty 5 Code No 7373465 Oil Absorbent Sheets Qty 5 Code No 7376847 Door Oil Absorbent Sheets Qty 5 Code No 7376839 Nozzle Skirt Qty 1 Code No 7373791 10 3 Consumables...

Page 41: ...s and appearance are subject to change without notice due to improvements Used to maintain optimum performance and prolong useful life of dental handpieces Delivers oil and air automatically to handpi...

Page 42: ...ged person people in dental clinic b Language Understanding English or other languages offered in the Instruction for Use Understanding of precautions and warnings c Experience Not relevant 11 2 Inten...

Page 43: ...imitation Humidity limitation Atmospheric pressure limi tation Prescription Device CAUTION Federal law restricts this device to sale by or on the order of a dentist Valid only for U S A cTUVus certifi...

Page 44: ...ce CISPR 11 Group 1 Class B This device uses RF energy only for its internal function There fore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipme...

Page 45: ...line s to earth Signal input output 1 2 kV line s to earth Mains power quality should be that of a typical commercial or hospital environ ment Voltage dips short interruptions and voltage variations...

Page 46: ...ter manufacturer E is the compliance level in V m and d is the recommended separation distance in meters m Field strengths from field RF transmitters as determined by an electromagnetic site survey a...

Page 47: ...45 None Essential Performance Cable Length No Interface s Max Cable Length Shielding Cable Classification 1 AC Power Cable 2 3 m 3 wire Un shielded AC Power Line...

Page 48: ......

Page 49: ......

Page 50: ......

Page 51: ......

Page 52: ...el 1 949 477 6050 Fax 1 949 477 6051 ba usa bienair com Bien Air France S rl 19 21 rue du 8 Mai 1945 94110 Arcueil France Tel 33 0 1 49 08 02 60 Fax 33 0 1 46 64 86 68 ba f bienair com Bien Air Italia...