Warning
Never service heater while it is plugged in, operating or hot.
Severe burns or electrical shock can occur.
Every 50 hours of operation: wash the filter with clean oil, or, if too
dirty, replace it, remove upper body parts and clean inside and ventila-
tor with compressed air, check correct attachment of H.T. connectors
to the electrodes and check H.T. cables, remove burner assembly, clean
and check electrode settings, adjust according to Fig.2.
Fig.2
13
2-3 mm
2,5 - 3 mm
GB